Literature DB >> 25226942

Study of parameters for evaluating flow reduction with stents in a sidewall aneurysm phantom model.

Chang Ho Yu1, Tae Kyu Kwon1.   

Abstract

The effect of stent design parameters such as porosity, pore density, number of strands, and strut angle to the artery were studied in vitro using particle image velocimetry (PIV). Five mesh stents were implanted into a sidewall aneurysm model. The flow features in a sidewall aneurysm silicone phantom model were investigated at a Reynolds number of 300. It was found that the lowest porosity stent had the best value for velocity and vorticity reduction in an aneurysm pocket. The stent with higher pore density had a tendency to decrease the mean and maximum velocities, but it was not superior to the effects of porosity. In addition, investigation of the evaluation system confirmed that higher stent strut angles to the parent artery had a tendency to lower mean velocity, as shown by PIV and CFD. However, this effect was relatively smaller compared to porosity and pore density. Our evaluation system suggested the best combinations of parameters for the development of an ideal stent would be lower porosity, higher pore density, and higher strut angle. The results obtained in this study indicated that our evaluation system could be useful for various purposes related to evaluation of endovascular interventional devices.

Entities:  

Keywords:  Particle Image Velocimetry (PIV); pore density; porosity; sidewall aneurysm; stent

Mesh:

Year:  2014        PMID: 25226942     DOI: 10.3233/BME-141055

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  3 in total

1.  In vitro angiographic comparison of the flow-diversion performance of five neurovascular stents.

Authors:  Ronak J Dholakia; Ari D Kappel; Andrew Pagano; Henry H Woo; Baruch B Lieber; David J Fiorella; Chander Sadasivan
Journal:  Interv Neuroradiol       Date:  2017-12-14       Impact factor: 1.610

2.  In vitro digital subtraction angiographic evaluation of flow diverters in a patient-specific aneurysm.

Authors:  Liang-Der Jou
Journal:  Interv Neuroradiol       Date:  2017-01-01       Impact factor: 1.610

3.  A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

Authors:  Andrzej Polanczyk; Marek Podyma; Lukasz Trebinski; Jaroslaw Chrzastek; Ireneusz Zbicinski; Ludomir Stefanczyk
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

  3 in total