Biomechanical evaluation of dental implants with three different designs: Removal torque and resonance frequency analysis in rabbits.

Sergio Alexandre Gehrke1, Giovanni Wiel Marin2.   

Abstract

The objective of this study was to investigate the effect of implant design on stability and resistance to reverse torque in the tibia of rabbits. Three test groups were prepared using the different characteristics of each implant model: square threads with progressive depth to the apex, a cervical portion without threads and a self-tapping system that is quite pronounced and aggressive (Group 1); triangular threads with flat tips with increasing thread depth from the cervical portion to the apex and a small self-tapping portion with a short thread pitch (Group 2); long thread pitch, progressive thread depth, an apical area with a small self-tapping portion (Group 3). For the two last groups, a final single-use drill was provided for each implant. Nine rabbits received 54 conical implants with a same surface treatment. The resonance frequency was analysed four times (0, 6, 8 and 12 weeks), and removal torque values were measured at three time intervals after the implantations (6, 8 and 12 weeks). In comparing the implant stability quotient at the four time points, highly significant statistic differences were found (p = 1.29(-10)). The reverse torque at the three time points was also significantly different among the groups (p = 0.00015). The implants of Group 2, with seemingly less aggressive design, more quickly reached high values of stability and removal torque. Under the limitations of this study, however, it is possible that in cases in which there may be low osseointegration response, the implant design should be evaluated.
Copyright © 2014 Elsevier GmbH. All rights reserved.

Entities:  

Keywords:  Animal study; Implant design; Osseointegration; Removal torque; Resonance frequency analysis

Mesh:

Substances:

Year:  2014        PMID: 25224495     DOI: 10.1016/j.aanat.2014.07.009

Source DB:  PubMed          Journal:  Ann Anat        ISSN: 0940-9602            Impact factor:   2.698


  7 in total

1.  Replacement of Destructive Pull-out Test with Modal Analysis in Primary Fixation Stability Assessment of Spinal Pedicle Screw.

Authors:  Mohammadjavad Einafshar; Ata Hashemi; Gerrit Harry van Lenthe
Journal:  Arch Bone Jt Surg       Date:  2022-02

2.  The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study.

Authors:  G Falisi; M Severino; C Rastelli; S Bernardi; S Caruso; M Galli; L Lamazza; C Di Paolo
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-03-01

3.  Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill.

Authors:  Sergio Alexandre Gehrke; Raphaél Bettach; Jaime Sardá Aramburú Júnior; Juan Carlos Prados-Frutos; Massimo Del Fabbro; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2018-04-11       Impact factor: 3.411

4.  Can the Macrogeometry of Dental Implants Influence Guided Bone Regeneration in Buccal Bone Defects? Histomorphometric and Biomechanical Analysis in Beagle Dogs.

Authors:  Manuel Fernández-Domínguez; Victor Ortega-Asensio; Elena Fuentes-Numancia; Juan Manuel Aragoneses; Horia Mihail Barbu; María Piedad Ramírez-Fernández; Rafael Arcesio Delgado-Ruiz; José Luis Calvo-Guirado; Nahum Samet; Sergio Alexandre Gehrke
Journal:  J Clin Med       Date:  2019-05-07       Impact factor: 4.241

5.  Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles.

Authors:  Sergio Alexandre Gehrke; Jaime Aramburú Júnior; Tiago Luis Eirles Treichel; Tales Dias do Prado; Berenice Anina Dedavid; Piedad N de Aza
Journal:  Sci Rep       Date:  2022-01-11       Impact factor: 4.996

6.  The Effect of Superstructures Connected to Implants with Different Surface Properties on the Surrounding Bone.

Authors:  Katsunori Koretake; Hiroshi Oue; Shinsuke Okada; Yosuke Takeda; Kazuya Doi; Yasumasa Akagawa; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2015-07-24

Review 7.  Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives.

Authors:  Elisabetta M Zanetti; Giulia Pascoletti; Michele Calì; Cristina Bignardi; Giordano Franceschini
Journal:  Biosensors (Basel)       Date:  2018-07-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.