Literature DB >> 25220298

Clinical Marginal and Internal Adaptation of Maxillary Anterior Single All-Ceramic Crowns and 2-year Randomized Controlled Clinical Trial.

Aslı Akın1, Suna Toksavul1, Muhittin Toman1.   

Abstract

PURPOSE: The aims of this randomized-controlled clinical trial were to compare marginal and internal adaptation of all-ceramic crowns fabricated with CAD/CAM and heat-pressed (HP) techniques before luting and to evaluate the clinical outcomes at baseline and at 6, 12, and 24 months after luting.
MATERIALS AND METHODS: Fifteen CAD/CAM (CC) and 15 HP all-ceramic crowns were placed in 15 patients. A silicone replica was obtained to measure marginal and internal adaptation of each all-ceramic crown before luting, and they were sectioned buccolingually and mesiodistally. Marginal and internal adaptations were measured using computerized light microscope at 40× magnification. Clinical evaluations took place at baseline (2 days after luting) and at 6, 12, and 24 months after luting. Replica scores were analyzed with Mann-Whitney U and Student's t-test (α = 0.05). Survival rate of crowns was determined using Kaplan-Meier statistical analysis.
RESULTS: The median marginal gap for the CC group was 132.2 μm and was 130.2 μm for the HP group. The mean internal adaptation for the CC group was 220.3 ± 51.3 μm and 210.5 ± 31 μm for the HP group. There were no statistically significant differences with respect to marginal opening (Mann-Whitney U test; p = 0.95) and internal adaptation (Student's t-test; p = 0.535) between the 2 groups. Based on modified Ryge criteria, 100% of the crowns were rated satisfactory during the 2-year period.
CONCLUSION: In this in vivo study, CAD/CAM and HP all-ceramic crowns exhibited similar marginal and internal adaptations. A 100% success rate was recorded for the 15 CAD/CAM and for the 15 HP all-ceramic crowns during the 2-year period.
© 2014 by the American College of Prosthodontists.

Entities:  

Keywords:  All-ceramic; CAD/CAM; heat-pressed; internal adaptation; marginal adaptation

Mesh:

Substances:

Year:  2014        PMID: 25220298     DOI: 10.1111/jopr.12217

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

1.  Remake Rates for Single-Unit Crowns in Clinical Practice: Findings from The National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; Mark S Litaker; Valeria V Gordan; Thomas Karr; Ellen Sowell; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2018-11-22       Impact factor: 2.752

2.  Early complications and performance of 327 heat-pressed lithium disilicate crowns up to five years.

Authors:  Fabian Huettig; Ulf Peter Gehrke
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.