Abstract

Superior tilt of the baseplate component in reverse total shoulder arthroplasty leads to tensile baseplate forces and may be a contributor to early loosening. The risk factors for this implant malposition include inadequate exposure through a superior approach and superior glenoid bone deficiency that obscures the native glenoid tilt. Here we review our preoperative evaluation and surgical management strategies to avoid superior tilt. Adequate exposure with a superior approach can be achieved but requires not just proper surgical technique but also careful patient selection. We propose that the superior approach be considered only for acute proximal humerus fractures or in patients when the following criteria are met: no prior open surgery on the shoulder; more than 30° of passive external rotation at 0° of abduction; no medial humeral osteophytes; and any superior migration must be reducible with a sulcus test during examination under anesthesia. Avoiding superior tilt when there is significant superior glenoid erosion can be accomplished with humeral head autograft, most easily performed through a deltopectoral approach. Preoperative templating is critical to determine proper graft thickness, inclination, reaming depth, and harvest technique.
Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Reverse; arthroplasty; bone; graft; shoulder; total

Mesh:

Year:  2014        PMID: 25220202     DOI: 10.1016/j.jse.2014.06.029

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  7 in total

1.  Does Humeral Component Lateralization in Reverse Shoulder Arthroplasty Affect Rotator Cuff Torque? Evaluation in a Cadaver Model.

Authors:  Kevin Chan; G Daniel G Langohr; Matthew Mahaffy; James A Johnson; George S Athwal
Journal:  Clin Orthop Relat Res       Date:  2017-06-14       Impact factor: 4.176

2.  CORR Insights®: Superior Baseplate Inclination Is Associated With Instability After Reverse Total Shoulder Arthroplasty.

Authors:  Edward G McFarland
Journal:  Clin Orthop Relat Res       Date:  2018-08       Impact factor: 4.176

Review 3.  Radiological changes, infections and neurological complications after reverse shoulder arthroplasty related to different design types and their rates: Part II.

Authors:  Marko Nabergoj; Patrick J Denard; Philippe Collin; Rihard Trebše; Alexandre Lädermann
Journal:  EFORT Open Rev       Date:  2021-11-19

Review 4.  Mechanical complications and fractures after reverse shoulder arthroplasty related to different design types and their rates: part I.

Authors:  Marko Nabergoj; Patrick J Denard; Philippe Collin; Rihard Trebše; Alexandre Lädermann
Journal:  EFORT Open Rev       Date:  2021-11-19

5.  A computed tomography analysis of three-dimensional glenoid orientation modified by glenoid torsion.

Authors:  Noboru Matsumura; Satoshi Oki; Taku Suzuki; Takuji Iwamoto; Kazuki Sato; Masaya Nakamura; Morio Matsumoto; Takeo Nagura
Journal:  JSES Open Access       Date:  2018-09-21

Review 6.  Preoperative glenoid considerations for shoulder arthroplasty: a review.

Authors:  Stephen Gates; Brain Sager; Michael Khazzam
Journal:  EFORT Open Rev       Date:  2020-03-02

Review 7.  Clinical outcomes and complications of reverse shoulder arthroplasty used for failed prior shoulder surgery: a systematic review and meta-analysis.

Authors:  Aaron J Bois; Paige Knight; Khalifa Alhojailan; Kamal I Bohsali
Journal:  JSES Int       Date:  2020-01-03