Literature DB >> 25219776

Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner.

Wicher J van der Meer1, Pieter U Dijkstra2, Anita Visser3, Arjan Vissink4, Yijin Ren5.   

Abstract

Volume changes in facial morphology can be assessed using the 3dMD DSP400 stereo-optical 3-dimensional scanner, which uses visible light and has a short scanning time. Its reliability and validity have not to our knowledge been investigated for the assessment of facial swelling. Our aim therefore was to assess them for measuring changes in facial contour, in vivo and in vitro. Twenty-four healthy volunteers with and without an artificial swelling of the cheek were scanned, twice in the morning and twice in the afternoon (in vivo measurements). A mannequin head was scanned 4 times with and without various externally applied artificial swellings (in vitro measurements). The changes in facial contour caused by the artificial swelling were measured as the change in volume of the cheek (with and without artificial swelling in place) using 3dMD Vultus software. In vivo and in vitro reliability expressed in intraclass correlations were 0.89 and 0.99, respectively. In vivo and in vitro repeatability coefficients were 5.9 and 1.3 ml, respectively. The scanner underestimated the volume by 1.2 ml (95% CI -0.9 to 3.4) in vivo and 0.2 ml (95% CI 0.02 to 0.4) in vitro. The 3dMD stereophotogrammetry scanner is a valid and reliable tool to measure volumetric changes in facial contour of more than 5.9 ml and for the assessment of facial swelling.
Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D stereophotogrammetry; 3dMD DSP400® stereo-optical 3D scanner; measurement; reliability; swelling

Mesh:

Substances:

Year:  2014        PMID: 25219776     DOI: 10.1016/j.bjoms.2014.08.019

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  10 in total

1.  Esthetic evaluation of facial cheek volume: A study using 3D stereophotogrammetry.

Authors:  Jie Feng; Hongyou Yu; Yijia Yin; Yinqiu Yan; Zheng Wang; Ding Bai; Xianglong Han
Journal:  Angle Orthod       Date:  2018-10-16       Impact factor: 2.079

2.  Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System.

Authors:  Ethan J Speir; C Matthew Hawkins; Michael J Weiler; Michael Briones; Rachel Swerdlin; Solomon Park; J Brandon Dixon
Journal:  J Digit Imaging       Date:  2019-04       Impact factor: 4.056

3.  Reproducibility of Three-Dimensional Volumetric Measurement of Periocular Tumor Models.

Authors:  Yongwei Guo; Ludwig M Heindl; Wanlin Fan; Alexander C Rokohl; Patrick Kupka; Xiaoyi Hou; Jinhua Liu; Senmao Li; Adam Kopecky; Sitong Ju; Philomena A Wawer Matos
Journal:  Ophthalmol Ther       Date:  2022-10-16

4.  Influence of Connecting Two Standalone Mobile Three-Dimensional Scanners on Accuracy Comparing with a Standard Device in Facial Scanning.

Authors:  Ali Modabber; Florian Peters; Anna Brokmeier; Evgeny Goloborodko; Alireza Ghassemi; Bernd Lethaus; Frank Hölzle; Stephan Christian Möhlhenrich
Journal:  J Oral Maxillofac Res       Date:  2016-12-28

5.  Clinical and Radiographic Characteristics as Predictive Factors of Swelling and Trismus after Mandibular Third Molar Surgery: A Longitudinal Approach.

Authors:  José Manuel Pérez-González; Vicente Esparza-Villalpando; Ricardo Martínez-Rider; Miguel Ángel Noyola-Frías; Amaury Pozos-Guillén
Journal:  Pain Res Manag       Date:  2018-04-23       Impact factor: 3.037

6.  Accuracy of three-dimensional photogrammetry and cone beam computed tomography based on linear measurements in patients with facial deformities.

Authors:  Zhenqi Zhao; Lizhe Xie; Dan Cao; Iman Izadikhah; Pengcheng Gao; Yang Zhao; Bin Yan
Journal:  Dentomaxillofac Radiol       Date:  2020-08-13       Impact factor: 2.419

7.  The influence of dexamethasone on postoperative swelling and neurosensory disturbances after orthognathic surgery: a randomized controlled clinical trial.

Authors:  W Semper-Hogg; M A Fuessinger; T W Dirlewanger; C P Cornelius; M C Metzger
Journal:  Head Face Med       Date:  2017-11-07       Impact factor: 2.151

8.  Effects of low-level laser therapy following surgical extraction of the lower third molar with objective measurement of swelling using a three-dimensional system.

Authors:  Mahmut Koparal; Ayse Ozcan Kucuk; Hilal Alan; Fatih Asutay; Mehmet Avci
Journal:  Exp Ther Med       Date:  2018-03-02       Impact factor: 2.447

9.  The Impact of the Use of Kinesio Taping Method on the Reduction of Swelling in Patients After Orthognathic Surgery: A Pilot Study.

Authors:  Danuta Lietz-Kijak; Edward Kijak; Marcin Krajczy; Katarzyna Bogacz; Jacek Łuniewski; Jan Szczegielniak
Journal:  Med Sci Monit       Date:  2018-06-04

10.  Scientific validation of three-dimensional stereophotogrammetry compared to the IGAIS clinical scale for assessing wrinkles and scars after laser treatment.

Authors:  Barbara Helena Barcaro Machado; Ivy Dantas De Melo E Silva; Walter Marou Pautrat; James Frame; Mohammad Najlah
Journal:  Sci Rep       Date:  2021-06-11       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.