Literature DB >> 25219587

Eigencorneas: application of principal component analysis to corneal topography.

Pablo Rodríguez1, Rafael Navarro, Jos J Rozema.   

Abstract

PURPOSE: To determine the minimum number of orthonormal basis functions needed to accurately represent the great majority of corneal topographies from a normal population.
METHODS: Principal Component Analysis was applied to the elevation topographies of the anterior and posterior corneal surfaces and central thickness of 368 eyes of 184 healthy subjects. PCA was applied directly to the input elevation data points and after fitting them to Zernike polynomials (up to 8th order, 8 mm diameter). The anterior and posterior surfaces, as well as right eye and left eye data, were analysed both separately and jointly. A threshold based on the amount of explained variance (99%) was applied to determine the minimum number of basis functions (eigencorneas) or degrees of freedom (DoF) in the population.
RESULTS: The eigenvectors directly obtained from elevation data resemble Zernike polynomials. The separate principal component analysis on the Zernike coefficients of anterior and posterior surfaces yielded 5 and 9 DoF, respectively. An additional reduction to 11 DoF (instead of 15 DoF) was achieved when performing a joint PCA that included both surfaces as well as central thickness. Finally, a further reduction was obtained by pooling right and left eye data together, to only 18 DoF.
CONCLUSIONS: The combination of Zernike fit and Principal Component Analysis yields a strong reduction of dimensionality of elevation topography data, to only 19 independent parameters (18 DoF plus population average), which indicates a high degree of correlation existing between anterior and posterior surfaces, and between eyes. The resulting eigencorneas are especially well suited for practical applications, as they are uncorrelated and orthonormal linear combinations of Zernike polynomials.
© 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

Entities:  

Keywords:  Zernike polynomials; corneal model; corneal topography; principal component analysis

Mesh:

Year:  2014        PMID: 25219587     DOI: 10.1111/opo.12155

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  1 in total

1.  Image quality eigenfunctions for the human eye.

Authors:  Pablo Rodríguez; Rafael Navarro; Jos J Rozema
Journal:  Biomed Opt Express       Date:  2019-10-21       Impact factor: 3.732

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.