Clinical Marginal and Internal Fit of Crowns Fabricated Using Different CAD/CAM Technologies.

Zhuoli Huang1, Lu Zhang1, Jingwei Zhu1, Yiwei Zhao1, Xiuyin Zhang1.   

Abstract

PURPOSE: The aims of this in vivo investigation were to compare the marginal and internal fit of single-unit crowns fabricated using a selective laser melting (SLM) procedure with two CAD/CAM grinding procedures, and to evaluate the influence of tooth type on the parameters measured.
MATERIALS AND METHODS: A total of 270 crowns were evaluated, including 90 SLM metal-ceramic crowns (group B), 90 zirconium-oxide-based ceramic crowns (group L), and 90 lithium disilicate ceramic crowns (group C). The marginal and internal gaps of the crowns were recorded using a replica technique with a silicone indicator paste stabilized with a light-body silicone. The gap replica specimen were sectioned buccolingually and mesiodistally and then examined using a stereomicroscope at 30× magnification. Ten reference points were measured on each anterior and premolar specimen, and 20 reference points were measured on each molar specimen. Two-way ANOVA was performed to identify the significant differences between the groups.
RESULTS: The mean marginal fit of group B was significantly better than those of group C and group L (p < 0.005), but a significant difference was not found between group C and group L (p > 0.05). The mean axial gap of group B was significantly smaller than those of group C and group L (p < 0.01), while group C was not different from group L (p > 0.05). The mean occlusal gap of group B was significantly higher than those of group C and group L (p < 0.05), and no difference was found between group C and group L (p > 0.05). The marginal and internal gaps of crowns varying according to tooth type were not significantly different (p > 0.05).
CONCLUSION: The SLM system demonstrated better marginal and internal fit compared to the two CAD/CAM grinding systems examined. Tooth type did not significantly influence the marginal or internal fit.
© 2014 by the American College of Prosthodontists.

Entities:  

Keywords:  CAD/CAM grinding technology; Fit; crown; selective laser melting

Mesh:

Substances:

Year:  2014        PMID: 25219401     DOI: 10.1111/jopr.12209

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  8 in total

1.  Influence of Teeth Preparation Finishing on the Adaptation of Lithium Disilicate Crowns.

Authors:  Bruna Salamoni Sinhori; Mauro Amaral Caldeira de Andrada; Guilherme Carpena Lopes; Sylvio Monteiro Junior; Luiz Narciso Baratieri
Journal:  Int J Biomater       Date:  2017-03-23

2.  Evaluation of Internal Fit and Marginal Adaptation of Provisional Crowns Fabricated with Three Different Techniques.

Authors:  Jie Wu; Hongjun Xie; Alireza Sadr; Kwok-Hung Chung
Journal:  Sensors (Basel)       Date:  2021-01-22       Impact factor: 3.576

3.  Evaluation of Physical Properties of Zirconia Suspension with Added Silane Coupling Agent for Additive Manufacturing Processes.

Authors:  Jae-Gon Jang; Jin-Ho Kang; Kwang-Bum Joe; Kumaresan Sakthiabirami; Kyoung-Jun Jang; Mee-Jin Jun; Gye-Jeong Oh; Chan Park; Sang-Won Park
Journal:  Materials (Basel)       Date:  2022-02-11       Impact factor: 3.623

4.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

5.  A 5-year randomized controlled trial comparing zirconia-based versus metal-based implant-supported single-tooth restorations in the premolar region.

Authors:  Mandana Hosseini; Nils Worsaae; Klaus Gotfredsen
Journal:  Clin Oral Implants Res       Date:  2022-06-11       Impact factor: 5.021

6.  Comparison of prosthetic models produced by traditional and additive manufacturing methods.

Authors:  Jin-Young Park; Hae-Young Kim; Ji-Hwan Kim; Jae-Hong Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

7.  Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings.

Authors:  Matthias Rödiger; Lea Schneider; Sven Rinke
Journal:  Biomed Res Int       Date:  2018-03-22       Impact factor: 3.411

8.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.