On the optimal measurement configuration for magnetic nanoparticles-enhanced breast cancer microwave imaging.

Ovidio Mario Bucci, Lorenzo Crocco, Rosa Scapaticci.   

Abstract

Magnetic nanoparticles-enhanced microwave imaging has been recently proposed as an effective and reliable means to detect breast cancer. Thanks to the nonmagnetic nature of human tissues, the imaging problem corresponds to the retrieval of a weak magnetic anomaly hosted into an unknown nonmagnetic scenario. Hence, properly targeted magnetic nanoparticles in principle allow to avoid false positives and reduce occurrence of false negatives. In this paper, we outline some guidelines for the design of the imaging device based on an optimized measurement configuration. In particular, we determine the nonredundant number of probes and their collocation needed to ensure a reliable solution of the underlying inverse scattering problem. The analysis exploits the spectral properties of the relevant mathematical operators and it is corroborated by reporting numerical results exploiting the phantoms' repository from the University of Wisconsin. It is shown that magnetic nanoparticles-enhanced microwave imaging can reliably detect cancer lesions even using low-complexity arrangements, designed according to the devised guidelines.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25216473     DOI: 10.1109/TBME.2014.2355411

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

Review 1.  Microwave Imaging for Early Breast Cancer Detection: Current State, Challenges, and Future Directions.

Authors:  Nour AlSawaftah; Salma El-Abed; Salam Dhou; Amer Zakaria
Journal:  J Imaging       Date:  2022-04-23

2.  Magnetic nanoparticles in cancer diagnosis, drug delivery and treatment.

Authors:  Meijia Wu; Shengwu Huang
Journal:  Mol Clin Oncol       Date:  2017-08-28

3.  A Discrete Dipole Approximation Solver Based on the COCG-FFT Algorithm and Its Application to Microwave Breast Imaging.

Authors:  Samar Hosseinzadegan; Andreas Fhager; Mikael Persson; Paul Meaney
Journal:  Int J Antennas Propag       Date:  2019-07-17       Impact factor: 1.174

4.  Assessing Patient-Specific Microwave Breast Imaging in Clinical Case Studies.

Authors:  Declan O'Loughlin; Muhammad Adnan Elahi; Benjamin R Lavoie; Elise C Fear; Martin O'Halloran
Journal:  Sensors (Basel)       Date:  2021-12-01       Impact factor: 3.576