Literature DB >> 2521538

Benefit of the perfusion catheter for emergency coronary artery grafting after failed percutaneous transluminal coronary angioplasty.

P Sundram1, J R Harvey, R G Johnson, M J Schwartz, D S Baim.   

Abstract

Of 2,102 consecutive patients who underwent percutaneous transluminal coronary angioplasty, 31 (1.5%) had emergency coronary bypass grafting for failed angioplasty. To determine the potential impact of different therapeutic strategies for controlling associated myocardial ischemia, 3 groups were analyzed. Group 1 comprised 11 patients (36%) in whom a "bailout" catheter was used to maintain anterograde coronary perfusion, group 2 included 16 patients (52%) in whom only intraaortic balloon counterpulsation was used and group 3 contained 4 patients (13%) in whom neither bailout catheter nor intraaortic balloon was used. Despite a longer average time to cardiopulmonary bypass, patients managed with the bailout catheter had a significantly lower incidence of Q-wave myocardial infarctions (9 vs 75%, p less than 0.05) compared with patients managed with intraaortic balloon counterpulsation alone. Those managed with the bailout catheter also had more consistent resolution of ST elevation and greater use of internal mammary artery grafts than patients supported by intraaortic balloon counterpulsation alone.

Entities:  

Mesh:

Year:  1989        PMID: 2521538     DOI: 10.1016/0002-9149(89)90331-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Myocardial protection during coronary angioplasty.

Authors:  P Angelini; D R Leachman; G Disciascio; M J Cowley; J A Brinker
Journal:  Tex Heart Inst J       Date:  1992

2.  Prediction of success and major complications during elective coronary angioplasty.

Authors:  A P Haasdijk; M J de Boer; H Suryapranata; J C A Hoorntje; F Zijlstra
Journal:  Neth Heart J       Date:  2001-04       Impact factor: 2.380

3.  Multivariate analysis in the prediction of death in hospital after acute myocardial infarction.

Authors:  Y Sahasakul; S Chaithiraphan; P Panchavinnin; P Jootar; V Thongtang; N Srivanasont; N Charoenchob; C Kangkagate
Journal:  Br Heart J       Date:  1990-09

4.  Temporary stent as a bail-out device during percutaneous transluminal coronary angioplasty: preliminary clinical experience.

Authors:  J S Gibbs; U Sigwart; N P Buller
Journal:  Br Heart J       Date:  1994-04

5.  Clinical experience of emergency coronary artery bypass grafting following failed percutaneous transluminal coronary angioplasty.

Authors:  Y Kioka; L Dallan; S Oliveira; A Jatene
Journal:  Jpn J Surg       Date:  1991-11

6.  Clinical experience with the Wiktor stent in native coronary arteries and coronary bypass grafts.

Authors:  S Vaishnav; S Aziz; C Layton
Journal:  Br Heart J       Date:  1994-09

7.  Aortic dissection with concomitant acute myocardial infarction: From diagnosis to management.

Authors:  Salvatore Lentini; Sossio Perrotta
Journal:  J Emerg Trauma Shock       Date:  2011-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.