| Literature DB >> 25214793 |
Aldo Innocente Galeandro1, Pietro Scicchitano2, Annapaola Zito2, Cristina Galeandro2, Michele Gesualdo2, Francesco Ciciarello3, Annagrazia Cecere2, Andrea Marzullo4, Vincenzo Contursi5, Annamaria Annicchiarico1, Marco Matteo Ciccone2.
Abstract
BACKGROUND: The reports of ultrasound evaluation of lower limb veins are difficult to understand by general practitioners (GPs) and physicians who are not specialized. We developed software for a three-dimensional (3D) electronic report of venous hemodynamic mapping (MEVeC(®)) in order to represent lower limb venous vasculature in a 3D way. The aim of the study is to compare the novel 3D report with the standard report.Entities:
Keywords: lower limb veins; standard report; ultrasound evaluation; vein 3D report
Mesh:
Year: 2014 PMID: 25214793 PMCID: PMC4159364 DOI: 10.2147/VHRM.S63068
Source DB: PubMed Journal: Vasc Health Risk Manag ISSN: 1176-6344
Figure 1Comparative representation of the standard report on paper (scheme on the left) and a two-dimensional (2D) report (scheme on the right).
Notes: The two black boxes represent the cross where superficial venous system links to deep venous one. In particular, the upper black block is the saphenous-femoral cross, while the middle black block is the saphenous-popliteal cross.
Figure 2Frontal, posterior, medial, and lateral view of the three-dimensional (3D) report (MEVeC®; Health Department, Tecnopolis, Science and Technology Park, University of Bari, Bari, Italy). The arrows directed downward express the presence of a venous reflux. The upward arrows indicate the continence of the veins. The interactions between deep and superficial veins are clearly expressed.
Figure 3The visual screen example appearing when performing a three-dimensional evaluation.
Figure 4The questionnaire adopted to compare a standard report and a three-dimensional MEVeC® (Health Department, Tecnopolis, Science and Technology Park, University of Bari, Bari, Italy) report.
Comparison between a three-dimensional (3D) electronic report (MEVeC®) and a standard report, according to questionnaire answersa
| Question | Standard report | 3D report | |
|---|---|---|---|
| 1 | 6.50±0.90 | 9.80±0.48 | <0.0001 |
| 2 | 6.23±1.04 | 9.30±0.79 | <0.0001 |
| 3 | 6.27±1.05 | 9.23±0.77 | <0.0001 |
| 4 | 6.33±1.06 | 8.80±0.92 | <0.0001 |
| 5 | 6.53±1.14 | 9.07±0.78 | <0.0001 |
| 6 | 6.27±1.28 | 9.00±0.83 | <0.0001 |
| 7 | 6.40±1.38 | 9.10±0.88 | <0.0001 |
| 8 | 6.57±1.43 | 9.27±0.74 | <0.0001 |
| 9 | 6.77±1.65 | 9.17±0.87 | <0.0001 |
| 10 | 6.50±1.33 | 9.00±0.98 | <0.0001 |
| 11 | 6.67±1.21 | 8.97±1.10 | <0.0001 |
| 12 | 6.67±1.03 | 8.83±1.26 | <0.0001 |
| 13 | 6.60±1.07 | 8.73±0.94 | <0.0001 |
Notes:
Data are expressed as mean ± standard deviation. Wilcoxon signed-rank test has been used for the comparisons between variables MEVeC® (Health Department, Tecnopolis, Science and Technology Park, University of Bari, Bari, Italy).
Percentile distribution of the scores from the questionnaire dealing with a comparison between a three-dimensional electronic report (MEVeC®) and a standard report
| Question | Report | Percentile
| |||
|---|---|---|---|---|---|
| 25th | 50th | 75th | |||
| 1 | Standard | 6.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 10.00 | 10.00 | 10.00 | ||
| 2 | Standard | 5.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 9.00 | 9.00 | 10.00 | ||
| 3 | Standard | 5.75 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 9.00 | 9.00 | 10.00 | ||
| 4 | Standard | 6.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 5 | Standard | 6.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 6 | Standard | 5.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 7 | Standard | 5.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 8 | Standard | 5.75 | 6.00 | 8.00 | <0.0001 |
| MEVeC® | 9.00 | 9.00 | 10.00 | ||
| 9 | Standard | 5.75 | 6.00 | 8.00 | <0.0001 |
| MEVeC® | 9.00 | 9.00 | 10.00 | ||
| 10 | Standard | 5.00 | 6.00 | 7.00 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 11 | Standard | 6.00 | 6.00 | 7.25 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 12 | Standard | 6.00 | 6.50 | 7.25 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 10.00 | ||
| 13 | Standard | 6.00 | 6.00 | 7.25 | <0.0001 |
| MEVeC® | 8.00 | 9.00 | 9.25 | ||
Note: MEVeC® (Health Department, Tecnopolis, Science and Technology Park, University of Bari, Bari, Italy).