Literature DB >> 25212815

Tracheal intubation with the Bonfils fiberscope in the difficult pediatric airway: a comparison with fiberoptic intubation.

Jost Kaufmann1, Michael Laschat, Thomas Engelhardt, Martin Hellmich, Frank Wappler.   

Abstract

BACKGROUND: Fiberoptic intubation (FOI) is the gold standard for the tracheal intubation in adults with a difficult airway. However, this technique is more difficult in the narrow pediatric airway and the evaluation of alternative devices in children remains desirable. The Bonfils fiberscope (BF) is well described for the difficult airway, but no clinical data assessing its use in the difficult pediatric airway are available.
METHODS: A controlled clinical study was conducted comparing BF and FOI in children and infants requiring tracheal intubation with a suspected difficult airway or who demonstrated a difficult airway which was unanticipated. Time to successful intubation, quality of imaging and ease of the intubation procedure were determined.
RESULTS: A total of 26 patients (46% infants) were studied, and all successfully intubated at the first attempt using either the BF or FOI. Mouth opening was restricted in 38% of patients. Time required for intubation was shorter with the BF (52 ± 22 s) compared with the FOI (83 ± 24 s, P = 0.008). The image quality (excellent in 73% vs. 45%, P = 0.129) and the ease of the procedure (excellent in 67% vs. 18%, P = 0.015) were considered better with BF than with FOI.
CONCLUSION: Although both the BF and FOI are suitable devices for the intubation of infants and children with difficult airways, the BF may allow faster tracheal intubation with a better image quality and ease of use.
© 2014 John Wiley & Sons Ltd.

Entities:  

Keywords:  Bronchoscopes; airway management; children; equipment; infants; intubation

Mesh:

Year:  2014        PMID: 25212815     DOI: 10.1111/pan.12523

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  6 in total

Review 1.  Development of endotracheal intubation devices for patients with tumors.

Authors:  Yang Liu; Yang Zhang; Bin Zhu; Wenyun Xu; Yi Yang; Zui Zou
Journal:  Am J Cancer Res       Date:  2022-06-15       Impact factor: 5.942

2.  Application of difficult endotracheal intubation under fluoroscopy in otorhinolaryngology head and neck surgery.

Authors:  Chenchen Zhang; Shuai Wang; Jianzhong Sang; Liang Wang; Yamin Zhang; Jin Sun; Meipan Yin; Yaozhen Ma; Gang Wu
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-05-30       Impact factor: 3.236

Review 3.  Evolution of videolaryngoscopy in pediatric population.

Authors:  Anju Gupta; Ridhima Sharma; Nishkarsh Gupta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-04-10

4.  Successful airway management using a MultiViewScope handle with a stylet scope in a patient with Schwartz-Jampel syndrome.

Authors:  Keika Mukaihara; Kohei Godai; Tomotsugu Yamada; Maiko Hasegawa-Moriyama; Yuichi Kanmura
Journal:  JA Clin Rep       Date:  2016-11-14

Review 5.  Optical Devices in Tracheal Intubation-State of the Art in 2020.

Authors:  Jan Matek; Frantisek Kolek; Olga Klementova; Pavel Michalek; Tomas Vymazal
Journal:  Diagnostics (Basel)       Date:  2021-03-22

6.  Noninvasive ventilation support during fiberoptic bronchoscopy-guided nasotracheal intubation effectively prevents severe hypoxemia.

Authors:  Lingbo Nong; Weibo Liang; Yuheng Yu; Yin Xi; Dongdong Liu; Jie Zhang; Jing Zhou; Chun Yang; Weiqun He; Xiaoqing Liu; Yimin Li; Rongchang Chen
Journal:  J Crit Care       Date:  2019-11-14       Impact factor: 3.425

  6 in total