Literature DB >> 25209366

Evaluation of near infrared fluorescent labeling of monoclonal antibodies as a tool for tissue distribution.

Kip P Conner1, Brooke M Rock2, Gayle K Kwon1, Joseph P Balthasar1, Lubna Abuqayyas1, Larry C Wienkers1, Dan A Rock2.   

Abstract

The pharmacokinetic (PK) behavior of monoclonal antibodies (mAbs) is influenced by target-mediated drug disposition, off-target effects, antidrug antibody-mediated clearance, and interaction with fragment-crystallizable domain (Fc) receptors such as neonatal Fc receptor. All of these interactions hold the potential to impact mAb biodistribution. Near infrared (NIR) fluorescent probes offer an approach complementary to radionuclides to characterize drug disposition. Notably, the use of FDA-approved IRDye800 (IR800; LI-COR, Lincoln, NE) as a protein-labeling agent in preclinical work holds the potential for quantitative tissue analysis. Here, we tested the utility of the IR800 dye as a quantitative mAb tracer during pharmacokinetic analysis in both plasma and tissues using a model mouse monoclonal IgG1 (8C2) labeled with ≤1.5 molecules of IR800. The plasma PK parameters derived from a mixture of IR800-8C2 and 8C2 dosed intravenously to C57BL/6 mice at 8 mg/kg exhibited a large discrepancy in exposure depending on the method of quantitation [CLplasma = 8.4 ml/d per kilogram (NIR fluorescence detection) versus 2.5 ml/d per kilogram (enzyme-linked immunosorbent assay)]. The disagreement between measurements suggests that the PK of 8C2 is altered by addition of the IR800 dye. Additionally, direct fluorescence analysis of homogenized tissues revealed several large differences in IR800-8C2 tissue uptake when compared with a previously published study using [(125)I]8C2, most notably an over 4-fold increase in liver concentration. Finally, the utility of IR800 in combination with whole body imaging was examined by comparison of IR800-8C2 levels observed in animal sagittal cross-sections to those measured in homogenized tissues. Our results represent the first PK analysis in both mouse plasma and tissues of an IR800-mAb conjugate and suggest that mAb disposition is significantly altered by IR800 conjugation to 8C2.
Copyright © 2014 by The American Society for Pharmacology and Experimental Therapeutics.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25209366     DOI: 10.1124/dmd.114.060319

Source DB:  PubMed          Journal:  Drug Metab Dispos        ISSN: 0090-9556            Impact factor:   3.922


  17 in total

1.  Biodistribution Analyses of a Near-Infrared, Fluorescently Labeled, Bispecific Monoclonal Antibody Using Optical Imaging.

Authors:  Norman C Peterson; George G Wilson; Qihui Huang; Nazzareno Dimasi; Kris F Sachsenmeier
Journal:  Comp Med       Date:  2016-04       Impact factor: 0.982

2.  Biodistribution of etanercept to tissues and sites of inflammation in arthritic rats.

Authors:  Xi Chen; Debra C DuBois; Richard R Almon; William J Jusko
Journal:  Drug Metab Dispos       Date:  2015-04-01       Impact factor: 3.922

3.  Residualization Rates of Near-Infrared Dyes for the Rational Design of Molecular Imaging Agents.

Authors:  Cornelius Cilliers; Jianshan Liao; Lydia Atangcho; Greg M Thurber
Journal:  Mol Imaging Biol       Date:  2015-12       Impact factor: 3.488

4.  Pharmacokinetic Modelling of Human Recombinant Protein, p75ECD-Fc: A Novel Therapeutic Approach for Treatment of Alzheimer's Disease, in Serum and Tissue of Sprague Dawley Rats.

Authors:  Sally Kelliny; Larisa Bobrovskaya; Xin-Fu Zhou; Richard Upton
Journal:  Eur J Drug Metab Pharmacokinet       Date:  2021-01-28       Impact factor: 2.441

5.  Imaging the Alternatively Spliced D Domain of Tenascin C in a Preclinical Model of Inflammatory Bowel Disease.

Authors:  Liang Zhang; Yuzhen Wang; Kristoff T Homan; Stephanie M Gaudette; Andrew J McCluskey; Ying Chan; Joanne Murphy; Mary Abdalla; Christine M Nelson; Victor Z Sun; Jamie E Erickson; Heather L Knight; Anca Clabbers; Annette J Schwartz Sterman; Soumya Mitra
Journal:  Mol Imaging Biol       Date:  2022-07-29       Impact factor: 3.484

6.  Dual-Modality Immuno-PET and Near-Infrared Fluorescence Imaging of Pancreatic Cancer Using an Anti-Prostate Stem Cell Antigen Cys-Diabody.

Authors:  Kirstin A Zettlitz; Wen-Ting K Tsai; Scott M Knowles; Naoko Kobayashi; Timothy R Donahue; Robert E Reiter; Anna M Wu
Journal:  J Nucl Med       Date:  2018-03-30       Impact factor: 10.057

Review 7.  Not so innocent: Impact of fluorophore chemistry on the in vivo properties of bioconjugates.

Authors:  Syed Muhammad Usama; Ek Raj Thapaliya; Michael P Luciano; Martin J Schnermann
Journal:  Curr Opin Chem Biol       Date:  2021-03-05       Impact factor: 8.972

8.  Safety and Stability of Antibody-Dye Conjugate in Optical Molecular Imaging.

Authors:  Jacqueline Pei; Georgina Juniper; Nynke S van den Berg; Naoki Nisho; Trevor Broadt; Anthony R Welch; Grace S Yi; Roan C Raymundo; Stefania U Chirita; Guolan Lu; Giri Krishnan; Yu-Jin Lee; Shrey Kapoor; Quan Zhou; A Dimitrios Colevas; Natalie S Lui; George A Poultsides; Gordon Li; Kurt R Zinn; Eben L Rosenthal
Journal:  Mol Imaging Biol       Date:  2020-09-03       Impact factor: 3.484

9.  Assessment of near-infrared fluorophores to study the biodistribution and tumor targeting of an IL13 receptor α2 antibody by fluorescence molecular tomography.

Authors:  Parul Gupta; Jo-Ann Wentland; Mauricio Leal; Dangshe Ma; Rachel Roach; Antonio Esparza; Lindsay King; Mary E Spilker; Cedo Bagi; Christopher T Winkelmann; Anand Giddabasappa
Journal:  Oncotarget       Date:  2017-07-26

10.  Multiplexed endoscopic imaging of Barrett's neoplasia using targeted fluorescent heptapeptides in a phase 1 proof-of-concept study.

Authors:  Jing Chen; Yang Jiang; Tse-Shao Chang; Bishnu Joshi; Juan Zhou; Joel H Rubenstein; Erik J Wamsteker; Richard S Kwon; Henry Appelman; David G Beer; Danielle K Turgeon; Eric J Seibel; Thomas D Wang
Journal:  Gut       Date:  2020-10-07       Impact factor: 31.793

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.