Literature DB >> 25207906

Use of the pipeline embolization device to treat recently ruptured dissecting cerebral aneurysms.

Robert S K Chan1, Calvin H K Mak2, Alain K S Wong2, Kwong Yau Chan2, Kar Ming Leung2.   

Abstract

The Pipeline embolization device (PED) is one of the flow-diverting stents approved for the treatment of unruptured large or wide-necked cerebral aneurysms in 2011(1). Its use has now been extended to the treatment of recently ruptured dissecting cerebral aneurysm, carotid pseudoaneurysm from radiation injury, and blister aneurysms(2,3). We aimed to evaluate the effectiveness of utilizing the PED as a primary treatment for ruptured dissecting intracranial aneurysms. A single center retrospective review was conducted for all patients primarily treated with PED for acute subarachnoid hemorrhage (SAH) from ruptured dissecting cerebral aneurysms between December 2010 and February 2013. Patients were followed up with CT angiogram (CTA) or digital subtraction angiogram (DSA). Eight patients with a total of eight dissecting aneurysms were identified. The mean duration from SAH to treatment was 2.5 days. Six of the aneurysms arose from vertebral arteries and two from the basilar artery. Immediate check-DSA confirmed satisfactory contrast stasis in all eight cases, and complete aneurysmal obliteration was achieved at six months. There were two (25%) procedure-related complications, but no major procedure-related complications, such as thromboembolic events or rebleeding from aneurysm were encountered. The PED is a feasible treatment option for ruptured dissecting cerebral aneurysms in acute phase. According to our experience, using PED as flow-diverters in acute SAH does not significantly increase the complication risks or mortality rate if the antiplatelet regime is carefully monitored. Future studies shall evaluate the optimal antiplatelet regimen for using the PED in the acute phase.

Entities:  

Keywords:  VerifyNow assay; dissecting aneurysms; pipeline embolization device; subarachnoid hemorrhage

Mesh:

Year:  2014        PMID: 25207906      PMCID: PMC4187439          DOI: 10.15274/INR-2014-10042

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  21 in total

1.  Endovascular treatment of a ruptured blood blister-like aneurysm with a flow-diverting stent.

Authors:  S Rasskazoff; J Silvaggio; P A Brouwer; A Kaufmann; A Nistor; D Iancu
Journal:  Interv Neuroradiol       Date:  2010-10-25       Impact factor: 1.610

2.  Vertebrobasilar dissection with subarachnoid hemorrhage: a retrospective study of 29 patients.

Authors:  B Ramgren; M Cronqvist; B Romner; L Brandt; S Holtås; E-M Larsson
Journal:  Neuroradiology       Date:  2005-02-16       Impact factor: 2.804

3.  The role of the pipeline embolization device for the treatment of dissecting intracranial aneurysms.

Authors:  M de Barros Faria; R Nella Castro; J Lundquist; E Scrivano; R Ceratto; A Ferrario; P Lylyk
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

4.  Immediate and midterm results following treatment of recently ruptured intracranial aneurysms with the Pipeline embolization device.

Authors:  W McAuliffe; J D Wenderoth
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-01       Impact factor: 3.825

Review 5.  Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis.

Authors:  Waleed Brinjikji; Mohammad H Murad; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  Stroke       Date:  2013-01-15       Impact factor: 7.914

6.  Pipeline embolization device in aneurysmal subarachnoid hemorrhage.

Authors:  J P Cruz; C O'Kelly; M Kelly; J H Wong; W Alshaya; A Martin; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-11       Impact factor: 3.825

7.  Dual antiplatelet therapy monitoring for neurointerventional procedures using a point-of-care platelet function test: a single-center experience.

Authors:  D H Lee; A Arat; H Morsi; H Shaltoni; J R Harris; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-15       Impact factor: 3.825

Review 8.  Clopidogrel nonresponsiveness in patients undergoing percutaneous coronary intervention with stenting: a systematic review and meta-analysis.

Authors:  Jaapjan D Snoep; Marcel M C Hovens; Jeroen C J Eikenboom; Johanna G van der Bom; J Wouter Jukema; Menno V Huisman
Journal:  Am Heart J       Date:  2007-08       Impact factor: 4.749

9.  Endovascular treatment for large and giant fusiform aneurysms of the vertebrobasilar arteries.

Authors:  Zhi Chen; Yunfeng Yang; Hongpin Miao; Weihua Tang; Jingyu Chen; Yin Niu; Hua Feng; Gang Zhu
Journal:  Clin Imaging       Date:  2013 Mar-Apr       Impact factor: 1.605

10.  Recurrent subarachnoid hemorrhage from untreated ruptured vertebrobasilar dissecting aneurysms.

Authors:  T Mizutani; T Aruga; T Kirino; Y Miki; I Saito; T Tsuchida
Journal:  Neurosurgery       Date:  1995-05       Impact factor: 4.654

View more
  8 in total

1.  Endovascular Treatment in Ruptured Middle Cerebral Artery Dissection Preservation of Arterial Continuity.

Authors:  Dong Hyuk Nam; Sang Kyu Park
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2015-06-30

2.  Patients with subarachnoid haemorrhage from vertebrobasilar dissection: treatment with stent-in-stent technique.

Authors:  Pervinder Bhogal; Patrick A Brouwer; Åsa Kuntze Söderqvist; Marcus Ohlsson; Tommy Andersson; Staffan Holmin; Michael Söderman
Journal:  Neuroradiology       Date:  2015-03-05       Impact factor: 2.804

3.  Clinical and angiographic outcomes in patients with intracranial aneurysms treated with the pipeline embolization device: intra-procedural technical difficulties, major morbidity, and neurological mortality decrease significantly with increased operator experience in device deployment and patient management.

Authors:  Josser E Delgado Almandoz; Yasha Kayan; Andrea Tenreiro; Adam N Wallace; Jill M Scholz; Jennifer L Fease; Anna M Milner; Maximilian Mulder; Kyle M Uittenbogaard; Oscar Tenreiro-Picón
Journal:  Neuroradiology       Date:  2017-10-06       Impact factor: 2.804

4.  Ruptured Basilar Artery Dissection Diagnosed Using Magnetic Resonance Vessel Wall Imaging and Treated with Coil Embolization with Overlapping LVIS Stents: A Case Report.

Authors:  Shinya Sonobe; Masahiro Yoshida; Kuniyasu Niizuma; Teiji Tominaga
Journal:  NMC Case Rep J       Date:  2020-03-24

5.  Transient third cranial nerve palsy after pipeline shield treatment of a ruptured anterior cerebral artery dissecting aneurysm: Case report.

Authors:  David Vergara-Garcia; Juan Felipe Abaunza-Camacho; Mariana Agudelo-Arrieta; William Mauricio Riveros; Alberto Caballero
Journal:  Surg Neurol Int       Date:  2021-09-30

Review 6.  The Use of Flow Diversion for the Treatment of Intracranial Aneurysms: Expansion of Indications.

Authors:  Adam M Brouillard; Xingwen Sun; Adnan H Siddiqui; Ning Lin
Journal:  Cureus       Date:  2016-01-28

7.  The use of flow diverters to treat small (≤5 mm) ruptured, saccular aneurysms.

Authors:  Pervinder Bhogal; Elina Henkes; Stefan Schob; Muhammad AlMatter; Victoria Hellstern; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes; Marta Aguilar Pérez
Journal:  Surg Neurol Int       Date:  2018-10-30

Review 8.  Outcomes after Flow Diverter Treatment in Subarachnoid Hemorrhage: A Meta-Analysis and Development of a Clinical Prediction Model (OUTFLOW).

Authors:  Michelle F M Ten Brinck; Viktoria E Shimanskaya; René Aquarius; Ronald H M A Bartels; Frederick J A Meijer; Petra C Koopmans; Guido de Jong; Ajay K Wakhloo; Joost de Vries; Hieronymus D Boogaarts
Journal:  Brain Sci       Date:  2022-03-15
  8 in total