Dosimetry of very high energy electrons (VHEE) for radiotherapy applications: using radiochromic film measurements and Monte Carlo simulations.

A Subiel1, V Moskvin, G H Welsh, S Cipiccia, D Reboredo, P Evans, M Partridge, C DesRosiers, M P Anania, A Cianchi, A Mostacci, E Chiadroni, D Di Giovenale, F Villa, R Pompili, M Ferrario, M Belleveglia, G Di Pirro, G Gatti, C Vaccarezza, B Seitz, R C Isaac, E Brunetti, S M Wiggins, B Ersfeld, M R Islam, M S Mendonca, A Sorensen, M Boyd, D A Jaroszynski.   

Abstract

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10(-5) neutrons cm(-2) per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25207591     DOI: 10.1088/0031-9155/59/19/5811

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

Review 1.  Laser-driven electron beam and radiation sources for basic, medical and industrial sciences.

Authors:  Kazuhisa Nakajima
Journal:  Proc Jpn Acad Ser B Phys Biol Sci       Date:  2015       Impact factor: 3.493

2.  Three electron beams from a laser-plasma wakefield accelerator and the energy apportioning question.

Authors:  X Yang; E Brunetti; D Reboredo Gil; G H Welsh; F Y Li; S Cipiccia; B Ersfeld; D W Grant; P A Grant; M R Islam; M P Tooley; G Vieux; S M Wiggins; Z M Sheng; D A Jaroszynski
Journal:  Sci Rep       Date:  2017-03-10       Impact factor: 4.379

3.  Deep Seated Tumour Treatments With Electrons of High Energy Delivered at FLASH Rates: The Example of Prostate Cancer.

Authors:  Alessio Sarti; Patrizia De Maria; Giuseppe Battistoni; Micol De Simoni; Cinzia Di Felice; Yunsheng Dong; Marta Fischetti; Gaia Franciosini; Michela Marafini; Francesco Marampon; Ilaria Mattei; Riccardo Mirabelli; Silvia Muraro; Massimiliano Pacilio; Luigi Palumbo; Loredana Rocca; Damiana Rubeca; Angelo Schiavi; Adalberto Sciubba; Vincenzo Tombolini; Marco Toppi; Giacomo Traini; Antonio Trigilio; Vincenzo Patera
Journal:  Front Oncol       Date:  2021-12-23       Impact factor: 6.244

4.  Dosimetry and radioprotection evaluations of very high energy electron beams.

Authors:  Thongchai A M Masilela; Rachel Delorme; Yolanda Prezado
Journal:  Sci Rep       Date:  2021-10-12       Impact factor: 4.379

5.  Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes.

Authors:  Luca Labate; Daniele Palla; Daniele Panetta; Federico Avella; Federica Baffigi; Fernando Brandi; Fabio Di Martino; Lorenzo Fulgentini; Antonio Giulietti; Petra Köster; Davide Terzani; Paolo Tomassini; Claudio Traino; Leonida A Gizzi
Journal:  Sci Rep       Date:  2020-10-14       Impact factor: 4.379

6.  First theoretical determination of relative biological effectiveness of very high energy electrons.

Authors:  Rachel Delorme; Thongchai A M Masilela; Camille Etoh; François Smekens; Yolanda Prezado
Journal:  Sci Rep       Date:  2021-05-27       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.