Migration of a broken steinman pin into the posterior compartment of the leg 12 years after total hip arthroplasty.

Ali Birjandinejad1, Mohammad Kaveh1, Amir R Fatehi1, Hami Ashraf1, Mohammad H Taraz Jamshidi1, Mohammad H Ebrahimzadeh1, Reza Shiravani1.   

Abstract

This report is on a migration of a Steinman pin into the posterior compartment of the calf. It was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. The puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. According to our literature review, migration of fixation pins through the knee joint is an extremely rare occurrence and could be missed by an inattentive physician.

Entities:  

Keywords:  Implant complication; Pin migration; Steinman pin; Total hip arthroplasty; Trochanter osteotomy

Year:  2013        PMID: 25207282      PMCID: PMC4151395     

Source DB:  PubMed          Journal:  Arch Bone Jt Surg        ISSN: 2345-461X


  10 in total

1.  Hemoptysis due to migration of a fractured Kirschner wire.

Authors:  G T Foster; K G Chetty; K Mahutte; J B Kim; S A Sasse
Journal:  Chest       Date:  2001-04       Impact factor: 9.410

Review 2.  Migration of pins used in operations on the shoulder.

Authors:  F A Lyons; C A Rockwood
Journal:  J Bone Joint Surg Am       Date:  1990-09       Impact factor: 5.284

3.  Intrathoracic migration of Steinman wire.

Authors:  Alpay Sarper; Mustafa Urgüden; Levent Dertsiz; Abid Demircan
Journal:  Interact Cardiovasc Thorac Surg       Date:  2003-06

4.  Late migration of threaded wire (schanz screw) from right distal clavicle to the cervical spine.

Authors:  Chun-Hao Tsai; Horng-Chaung Hsu; Chun-Yin Huan; Hsien-Te Chen; Yi-Chin Fong
Journal:  J Chin Med Assoc       Date:  2009-01       Impact factor: 2.743

5.  [Unusual migration of K-wire following fixation of clavicle fracture: a case report].

Authors:  Murat Bezer; Nuri Aydin; Bülent Erol; Tunç Laçin; Osman Güven
Journal:  Ulus Travma Acil Cerrahi Derg       Date:  2009-05

6.  Migrating foreign body in mediastinum--intravascular Steinman pin.

Authors:  Rajiv Sharma; Robert K Tam
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-02-05

7.  Migration of intra-articular K-wire into the contralateral pelvis after surgery for developmental dysplasia of the hip: a case report.

Authors:  Müslim Yurtçu; Hakan Senaran; Hakan H Türk; Adnan Abasıyanık; Ibrahim Tuncay
Journal:  Acta Orthop Traumatol Turc       Date:  2010       Impact factor: 1.511

8.  Intrathoracic migration of Kirschner pins.

Authors:  N Venissac; M Alifano; M Dahan; J Mouroux
Journal:  Ann Thorac Surg       Date:  2000-06       Impact factor: 4.330

Review 9.  [Spinal migration of a Kirschner wire after surgery for clavicular nonunion. A case report and review of the literature].

Authors:  W Mamane; D Breitel; T Lenoir; P Guigui
Journal:  Chir Main       Date:  2009-09-17

10.  Migration to the popliteal fossa of broken wires from a fixed patellar fracture.

Authors:  Ho-Rim Choi; Kyung-Dae Min; Sang-Wook Choi; Byung-Ill Lee
Journal:  Knee       Date:  2008-08-27       Impact factor: 2.199

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.