Factors that drive insulin-dosing decisions of diabetes care providers: a vignette-based study in the Netherlands.

A C R Simon1, J E Schopman, J B L Hoekstra, A Abu-Hanna, V E A Gerdes, N Peek, F Holleman.   

Abstract

AIM: To test how certain patient factors would influence the decision of Dutch care providers regarding insulin dose adjustments. We hypothesize that some of these decisions would diverge from recent evidence and consensus statements.
METHODS: We developed narrative vignettes describing clinical scenarios of patients receiving basal insulin therapy. For each vignette, the respondents were asked to indicate whether they would advise a change in insulin dose. A total of 520 paper questionnaires were distributed among physicians and nurses in primary and secondary care in the Netherlands. Multivariate linear and logistic regression analyses were performed to identify factors associated with dosing decisions.
RESULTS: A total of 190 (37%) questionnaires were returned. In cases of a severe rather than mild hypoglycaemic event, care providers were nearly five times more likely to decrease the dose (odds ratio 4.77, 95% CI 1.65-13.75). Care providers were six times more likely to increase the dose when the patient's current dose was low (30 units) rather than high (90 units) (odds ratio 6.38, 95% CI 3.04-13.37). The plasma glucose concentration during a hypoglycaemic event and a known history of cardiovascular disease did not influence the care providers' dosing decisions.
CONCLUSION: Evidence regarding the optimum insulin titration is not always translated into clinical practice. When formulating guidelines, misconceptions should be identified and addressed.
© 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25204362     DOI: 10.1111/dme.12586

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  2 in total

1.  Adjustment of insulin doses when switching from glargine 100 U/ml or detemir to degludec: an observational study.

Authors:  C Lualdi; A Silverii; I Dicembrini; L Pala; M Monami; E Mannucci
Journal:  J Endocrinol Invest       Date:  2018-07-09       Impact factor: 4.256

2.  Adjustment of Insulin Pump Settings in Type 1 Diabetes Management: Advisor Pro Device Compared to Physicians' Recommendations.

Authors:  Revital Nimri; Tal Oron; Ido Muller; Ivana Kraljevic; Montserrat Martín Alonso; Paivi Keskinen; Tanja Milicic; Asaf Oren; Athanasios Christoforidis; Marieke den Brinker; Lutgarda Bozzetto; Andrea Mario Bolla; Michal Krcma; Rosa Anna Rabini; Shadi Tabba; Lizl Smith; Andriani Vazeou; Giulio Maltoni; Elisa Giani; Eran Atlas; Moshe Phillip
Journal:  J Diabetes Sci Technol       Date:  2020-10-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.