Min-Hyeok Kang1, Ji-Won Kim2, Yang-Gon Kim3, Jun-Seok Kim3, Jae-Seop Oh4.
Abstract
[Purpose] The purpose of this study was to investigate the intra-rater reliability of measures of scapular protraction strength using a novel method. [Subjects] Forty-nine healthy subjects participated in this study. [Methods] Subjects performed maximal isometric scapular protraction on the left and right sides in the supine and seated positions. During scapular protraction, resistance was applied to the olecranon, and the strength of scapular protraction was measured using a load cell. Intra-rater reliability was calculated as the intra-class correlation coefficient (ICC3,1).Entities:
Keywords: Reliability; Scapular protraction; Serratus anterior
Year: 2014 PMID: 25202171 PMCID: PMC4155210 DOI: 10.1589/jpts.26.1153
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Fig. 1.Measure of the scapular protraction strength using a new force measurement device
The intra-class correlation coefficients and 95% confidence intervals for measures of scapular protraction strength
| Side | Supine position | Seated position | ||
|---|---|---|---|---|
| ICC | 95% CI | ICC | 95% CI | |
| Left | 0.97 | 0.96–0.98 | 0.98 | 0.97–0.99 |
| Right | 0.97 | 0.96–0.98 | 0.97 | 0.95–0.98 |
ICC, intra-class correlation coefficient; CI, confidence interval