Literature DB >> 25198817

The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study.

Francesca Rossetti1, Mauro Pittiruti, Massimo Lamperti, Ugo Graziano, Davide Celentano, Giuseppe Capozzoli.   

Abstract

PURPOSE: The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients.
METHODS: We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (<4 years, n = 157), B (4-11 years, n = 119), and C (12-18 years, n = 31). IC-ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina.
RESULTS: There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%.
CONCLUSIONS: We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.

Entities:  

Mesh:

Year:  2014        PMID: 25198817     DOI: 10.5301/jva.5000281

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  12 in total

1.  [Efficiency of electrocardiogram monitor for positioning the catheter tip in peripherally inserted central catheter placement in neonates].

Authors:  Qi-Ying Ling; Hong Chen; Min Tang; Yi Qu; Bin-Zhi Tang
Journal:  Zhongguo Dang Dai Er Ke Za Zhi       Date:  2018-05

2.  Retrospective Assessment of Patient and Catheter Characteristics Associated With Malpositioned Central Venous Catheters in Pediatric Patients.

Authors:  Mark D Weber; Thomas Conlon; Charlotte Woods-Hill; Stephanie L Watts; Eileen Nelson; Danielle Traynor; Bingqing Zhang; Daniela Davis; Adam S Himebauch
Journal:  Pediatr Crit Care Med       Date:  2022-03-01       Impact factor: 3.624

3.  Confirming longline position in neonates - Survey of practice in England and Wales.

Authors:  Arunoday Arunoday; Christos Zipitis
Journal:  World J Clin Pediatr       Date:  2017-08-08

4.  An Accuracy Study of the Intracavitary Electrocardiogram (IC-ECG) Guided Peripherally Inserted Central Catheter Tip Placement among Neonates.

Authors:  Lian-Juan Zhou; Hong-Zhen Xua; Mei-Fang Xu; Yan Hu; Xiao-Fang Lou
Journal:  Open Med (Wars)       Date:  2017-05-22

5.  Superior success rate of intracavitary electrocardiogram guidance for peripherally inserted central catheter placement in patients with cancer: A randomized open-label controlled multicenter study.

Authors:  Ling Yuan; Rongmei Li; Aifeng Meng; Yuling Feng; Xiancui Wu; Yiqun Yang; Ping Chen; Zhenzhu Qiu; Jing Qi; Chuanying Chen; Jia Wei; Minyi Qin; Weiwei Kong; Xiangyu Chen; Wei Xu
Journal:  PLoS One       Date:  2017-03-09       Impact factor: 3.240

6.  The safety and accuracy of ECG-guided PICC tip position verification applied in patients with atrial fibrillation.

Authors:  Yufang Gao; Yuxiu Liu; Hui Zhang; Fang Fang; Lei Song
Journal:  Ther Clin Risk Manag       Date:  2018-06-06       Impact factor: 2.423

7.  Comparative Study of Three Methods for Depth of Central Venous Catheter Placement in Children: An Observational Pilot Study.

Authors:  Vaishali Chaskar; Priyanka Pradeep Karnik; Nandini Malay Dave; Madhu Garasia
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-04-01

Review 8.  Supraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates.

Authors:  Zied Merchaoui; Ulrik Lausten-Thomsen; Florence Pierre; Maher Ben Laiba; Nolwenn Le Saché; Pierre Tissieres
Journal:  Front Pediatr       Date:  2017-10-05       Impact factor: 3.418

9.  A randomized controlled study of bedside electrocardiograph-guided tip location technique & the traditional chest radiography tip location technique for peripherally inserted central venous catheter in cancer patients.

Authors:  AiMin Li; JianGuo Jiao; Ying Zhang; Li Tian; JinHong Miao; XiaoLi Hao; ZhenChang Sun; QiaoZhi Sun
Journal:  Indian J Med Res       Date:  2018-05       Impact factor: 2.375

10.  Influence of guide wire removal on tip location in peripherally inserted central catheters (PICCs): a retrospective cross-sectional study.

Authors:  Dan Wang; Fangfang Niu; Huining Gao; Mingkai Yu; Yuhang Li; Liqun Xu; Huizhi Cao; Lili Wang; Jinhua Liu; Xue Ding; Ying Wang; Chen Yu; Huiyan Li; Kaijiang Yu; Changsong Wang
Journal:  BMJ Open       Date:  2019-10-31       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.