Literature DB >> 25196608

Spatial distortion due to field inhomogeneity in 3.0 tesla intraoperative MRI.

Asim F Choudhri1, Eric M Chin2, Paul Klimo3, Frederick A Boop3.   

Abstract

We describe a 14-year-old boy with a pilocytic astrocytoma of the left caudate head. Preoperative localization MR imaging (MRI) was performed in the operating room, and spatial distortion was noted felt to be related to head positioning relative to the isocenter of the magnetic field. The distortion artifact was subtle enough to be difficult to detect, but large enough to change the location of the lesion potentially leading to a non-diagnostic stereotactic biopsy. Repeat imaging after changing the head position to allow scanning closer to the isocenter of the magnetic field showed decreased distortion, an improvement greater than that using the manufacturer's distortion correction algorithm on the initial images. Intraoperative MRI, and its requisite limitations in positioning, requires vigilance to detect possible distortion that could alter surgical outcomes if not identified and corrected prospectively.

Entities:  

Keywords:  artifact; brain tumor; intraoperative MRI; magnetic resonance imaging

Mesh:

Year:  2014        PMID: 25196608      PMCID: PMC4236867          DOI: 10.15274/NRJ-2014-10081

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  5 in total

1.  Correction of B0 susceptibility induced distortion in diffusion-weighted images using large-deformation diffeomorphic metric mapping.

Authors:  Hao Huang; Can Ceritoglu; Xin Li; Anqi Qiu; Michael I Miller; Peter C M van Zijl; Susumu Mori
Journal:  Magn Reson Imaging       Date:  2008-05-21       Impact factor: 2.546

2.  Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery.

Authors:  V M Tronnier; C R Wirtz; M Knauth; G Lenz; O Pastyr; M M Bonsanto; F K Albert; R Kuth; A Staubert; W Schlegel; K Sartor; S Kunze
Journal:  Neurosurgery       Date:  1997-05       Impact factor: 4.654

3.  Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery.

Authors:  T S Sumanaweera; J R Adler; S Napel; G H Glover
Journal:  Neurosurgery       Date:  1994-10       Impact factor: 4.654

4.  Intraoperative MR imaging: preliminary results with 3 tesla MR system.

Authors:  M N Pamir; S Peker; M M Ozek; A Dinçer
Journal:  Acta Neurochir Suppl       Date:  2006

5.  3T intraoperative MRI for management of pediatric CNS neoplasms.

Authors:  A F Choudhri; P Klimo; T S Auschwitz; M T Whitehead; F A Boop
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-24       Impact factor: 3.825

  5 in total
  3 in total

1.  MRI quality control for the Italian Neuroimaging Network Initiative: moving towards big data in multiple sclerosis.

Authors:  Loredana Storelli; Maria A Rocca; Patrizia Pantano; Elisabetta Pagani; Nicola De Stefano; Gioacchino Tedeschi; Paola Zaratin; Massimo Filippi
Journal:  J Neurol       Date:  2019-08-17       Impact factor: 4.849

2.  3T intraoperative MRI for management of pediatric CNS neoplasms.

Authors:  A F Choudhri; P Klimo; T S Auschwitz; M T Whitehead; F A Boop
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-24       Impact factor: 3.825

Review 3.  Intraoperative MRI in pediatric brain tumors.

Authors:  Asim F Choudhri; Adeel Siddiqui; Paul Klimo; Frederick A Boop
Journal:  Pediatr Radiol       Date:  2015-09-07
  3 in total