BACKGROUND: Ventilation/perfusion single-emission photon CT (V/P-SPECT) is widely used to detect pulmonary embolism (PE). Any pathological deficit on P-SPECT with a corresponding unremarkable V-SPECT is considered an embolism. This means that a deficit on P-SPECT with a corresponding deficit on the ventilation scan correlates with other lung pathologies such as pneumonia, bullous emphysema or tumor. In principle, it is possible to identify any of these lung pathologies on nonenhanced chest CT and so this technique has the potential to replace V-SPECT in the diagnosis of PE. Today, SPECT/CT hybrid imaging systems are increasingly applied in clinical routines. OBJECTIVES: We investigated whether embolism can be diagnosed using a combined P-SPECT/CT hybrid imaging approach without V-SPECT. METHODS: Ninety-three patients with clinically suspected embolism were investigated with standard V/P-SPECT and a nonenhanced CT scan on a combined SPECT/CT system. A diagnosis of embolism was based on V/P-SPECT (gold standard). P-SPECT/CT datasets were blinded and analyzed without any knowledge of the V-SPECT data. The accuracy of P-SPECT/CT was compared to the gold standard. RESULTS: Embolism was diagnosed in 24/93 patients using V/P-SPECT. In total, 57 lung lobes were affected. P-SPECT/CT significantly (p < 0.01) overdiagnosed embolism in nonaffected patients. In total, 36 cases with 88 affected lung lobes were shown. The sensitivity was 95.8%, the specificity 82.6%, the false-negative rate 4.2% and the false-positive rate 17.3%. CONCLUSIONS: Our results demonstrate that a nonenhanced CT scan in a novel hybrid imaging system cannot replace V-SPECT in the scintigraphy-based diagnosis of PE. V-SPECT increases specificity and reduces the number of false-positive results when compared to 'perfusion-only' SPECT/CT.
BACKGROUND: Ventilation/perfusion single-emission photon CT (V/P-SPECT) is widely used to detect pulmonary embolism (PE). Any pathological deficit on P-SPECT with a corresponding unremarkable V-SPECT is considered an embolism. This means that a deficit on P-SPECT with a corresponding deficit on the ventilation scan correlates with other lung pathologies such as pneumonia, bullous emphysema or tumor. In principle, it is possible to identify any of these lung pathologies on nonenhanced chest CT and so this technique has the potential to replace V-SPECT in the diagnosis of PE. Today, SPECT/CT hybrid imaging systems are increasingly applied in clinical routines. OBJECTIVES: We investigated whether embolism can be diagnosed using a combined P-SPECT/CT hybrid imaging approach without V-SPECT. METHODS: Ninety-three patients with clinically suspected embolism were investigated with standard V/P-SPECT and a nonenhanced CT scan on a combined SPECT/CT system. A diagnosis of embolism was based on V/P-SPECT (gold standard). P-SPECT/CT datasets were blinded and analyzed without any knowledge of the V-SPECT data. The accuracy of P-SPECT/CT was compared to the gold standard. RESULTS:Embolism was diagnosed in 24/93 patients using V/P-SPECT. In total, 57 lung lobes were affected. P-SPECT/CT significantly (p < 0.01) overdiagnosed embolism in nonaffected patients. In total, 36 cases with 88 affected lung lobes were shown. The sensitivity was 95.8%, the specificity 82.6%, the false-negative rate 4.2% and the false-positive rate 17.3%. CONCLUSIONS: Our results demonstrate that a nonenhanced CT scan in a novel hybrid imaging system cannot replace V-SPECT in the scintigraphy-based diagnosis of PE. V-SPECT increases specificity and reduces the number of false-positive results when compared to 'perfusion-only' SPECT/CT.
Authors: Katherina P Farr; Stine Kramer; Azza A Khalil; Anni Morsing; Cai Grau Journal: Eur J Nucl Med Mol Imaging Date: 2015-04-11 Impact factor: 9.236
Authors: Ana Cristina Lopes Albricker; Cláudia Maria Vilas Freire; Simone Nascimento Dos Santos; Monica Luiza de Alcantara; Mohamed Hassan Saleh; Armando Luis Cantisano; José Aldo Ribeiro Teodoro; Carmen Lucia Lascasas Porto; Salomon Israel do Amaral; Orlando Carlos Gloria Veloso; Ana Cláudia Gomes Pereira Petisco; Fanilda Souto Barros; Márcio Vinícius Lins de Barros; Adriano José de Souza; Marcone Lima Sobreira; Robson Barbosa de Miranda; Domingos de Moraes; Carlos Gustavo Yuji Verrastro; Alexandre Dias Mançano; Ronaldo de Souza Leão Lima; Valdair Francisco Muglia; Cristina Sebastião Matushita; Rafael Willain Lopes; Artur Martins Novaes Coutinho; Diego Bromfman Pianta; Alair Augusto Sarmet Moreira Damas Dos Santos; Bruno de Lima Naves; Marcelo Luiz Campos Vieira; Carlos Eduardo Rochitte Journal: Arq Bras Cardiol Date: 2022-04 Impact factor: 2.000
Authors: Nishant Kumar; Karen Xie; Winnie Mar; Thomas M Anderson; Benjamin Carney; Nikhil Mehta; Roberto Machado; Michael J Blend; Yang Lu Journal: Nucl Med Mol Imaging Date: 2015-08-08
Authors: Ali Afshar-Oromieh; Helmut Prosch; Cornelia Schaefer-Prokop; Karl Peter Bohn; Ian Alberts; Clemens Mingels; Majda Thurnher; Paul Cumming; Kuangyu Shi; Alan Peters; Silvana Geleff; Xiaoli Lan; Feng Wang; Adrian Huber; Christoph Gräni; Johannes T Heverhagen; Axel Rominger; Matthias Fontanellaz; Heiko Schöder; Andreas Christe; Stavroula Mougiakakou; Lukas Ebner Journal: Eur J Nucl Med Mol Imaging Date: 2021-05-01 Impact factor: 9.236