Literature DB >> 25194302

Disparate response of high-frequency ganglionic plexus stimulation on sinus node function and atrial propagation in patients with atrial fibrillation.

Sébastien P J Krul1, Veronique M F Meijborg1, Wouter R Berger1, André C Linnenbank2, Antoine H G Driessen1, Wim-Jan van Boven1, Arthur A M Wilde1, Jacques M de Bakker2, Ruben Coronel3, Joris R de Groot4.   

Abstract

BACKGROUND: In patients with atrial fibrillation (AF), the autonomic nervous system is supposed to play an role in triggering AF; however, little is known of the effect on atrial conduction characteristics.
OBJECTIVE: The purpose of this study was to study the effect of ganglionic plexus (GP) stimulation during sinus rhythm on atrial and pulmonary vein conduction in patients during thoracoscopic surgery for AF
METHODS: In 25 patients, the anterior right ganglionic plexus (ARGP) was stimulated (16 Hz, at 1, 2, and 5 mA). Epicardial electrograms were recorded using a 48-electrode map from the right pulmonary vein (RPV) or right atrial (RA). Intra-atrial activation time (IAT), local activation time (LAT), and inhomogeneity of conduction (IIC) were determined. ECG parameters (P-P, P-R interval) were measured.
RESULTS: P-P interval was 956 ± 157 ms (range 768-1368 ms), and P-R interval was 203 ± 37 ms (range 136-280 ms). After ARGP stimulation, a short-lasting increase of P-P interval was observed, more prominent at higher output (1 mA = 82 ms, 2 mA = 180 ms, 5 mA = 268 ms, all P <.01 vs baseline). P-R interval remained unchanged. IAT was 34.4 ms (range 5.6-50.3 ms) at the RA and 105.8 ms (range 79.7-163.3 ms) at the RPV. After 1-mA stimulation IAT increased, in patients taking beta-blockers (P = .001), or it decreased, and this change persisted after subsequent stimulation at higher current (1 mA, P = .001; 2 mA, P = .401; 5 mA, P = .593). Similar changes were observed for LAT and IIC.
CONCLUSION: ARGP stimulation results in a short-lasting, output-dependent decrease in sinus node frequency due to a parasympathetic response. Stimulation of the ARGP induced a prolonged increase or decrease in conduction characteristics in patients with AF, consistent with a persistent differential parasympathetic and/or sympathetic response.
Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Atrial fibrillation; Atrium; Autonomic nervous system; Conduction; Ganglionic plexus; High-frequency stimulation; Sinoatrial node; Thoracoscopic surgery

Mesh:

Year:  2014        PMID: 25194302     DOI: 10.1016/j.hrthm.2014.04.041

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  4 in total

1.  Anesthetizing the Fibrillating Heart.

Authors:  Peter Hanna; Ching Zhu; Pradeep S Rajendran; Kalyanam Shivkumar
Journal:  J Am Heart Assoc       Date:  2019-05-21       Impact factor: 5.501

2.  Acetylcholine Delays Atrial Activation to Facilitate Atrial Fibrillation.

Authors:  Jason D Bayer; Bastiaan J Boukens; Sébastien P J Krul; Caroline H Roney; Antoine H G Driessen; Wouter R Berger; Nicoline W E van den Berg; Arie O Verkerk; Edward J Vigmond; Ruben Coronel; Joris R de Groot
Journal:  Front Physiol       Date:  2019-09-04       Impact factor: 4.566

3.  Open-chest Pulsed Electric Field Ablation of Cardiac Ganglionated Plexi in Acute Canine Models.

Authors:  Martin van Zyl; Mariam Khabsa; Jason A Tri; Thomas P Ladas; Omar Z Yasin; Adetola O Ladejobi; John Reilly; Barry O'Brien; Kenneth Coffey; Samuel J Asirvatham
Journal:  J Innov Card Rhythm Manag       Date:  2022-07-15

4.  Clinical course of sinus node dysfunction after thoracoscopic surgery for atrial fibrillation-analysis of the Atrial Fibrillation Ablation and Autonomic Modulation via Thoracoscopic Surgery (AFACT) study.

Authors:  Jolien Neefs; Shaëlle A Ons; Wouter R Berger; Sébastien P J Krul; Nicoline W E van den Berg; Femke R Piersma; Marcel A M Beijk; WimJan P van Boven; Antoine H G Driessen; Joris R de Groot
Journal:  J Interv Card Electrophysiol       Date:  2020-03-14       Impact factor: 1.900

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.