Literature DB >> 25192947

Percutaneous endovascular salvage techniques for implanted venous access device dysfunction.

Stéphane Breault1, Frédéric Glauser, Malik Babaker, Francesco Doenz, Salah Dine Qanadli.   

Abstract

PURPOSE: Implanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques. METHODS AND MATERIALS: Through a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new "mechanical adhesiolysis" maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.
RESULTS: Eighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.
CONCLUSION: These IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25192947     DOI: 10.1007/s00270-014-0968-0

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

1.  Brachial Approach As an Alternative Technique of Fibrin Sheath Removal for Implanted Venous Access Devices.

Authors:  Charalampos Sotiriadis; Steven David Hajdu; Francesco Doenz; Salah D Qanadli
Journal:  Front Surg       Date:  2017-04-10

Review 2.  Insights Into Endovascular Management of Superior Vena Cava Obstructions.

Authors:  Alexandre Ponti; Sarah Saltiel; David C Rotzinger; Salah D Qanadli
Journal:  Front Cardiovasc Med       Date:  2021-11-24
  2 in total