Literature DB >> 25192433

Total spherical aberration of the cornea in patients with cataract.

Ugo de Sanctis1, Luisa Vinai, Elena Bartoli, Piero Donna, Federico Grignolo.   

Abstract

PURPOSE: To investigate the distribution of corneal spherical aberration in patients with cataract using the Pentacam HR.
METHODS: Consecutive cataract patients were examined using the Pentacam HR high-resolution rotating Scheimpflug camera (Oculus, Wetzlar, Germany). In one eye of each patient, the root-mean-square (RMS) of anterior, posterior, and total corneal spherical aberration Z4(0) was calculated by ray-tracing on an area of 6 mm diameter. The Pearson correlation coefficient (r) was used to assess correlations between Z4(0) RMS values and age/total corneal refractive power. The χ2 test was used to compare the proportion of eyes qualifying for spherically neutral or negatively aspheric (-0.17 and -0.27 μm) intraocular lenses (IOLs) by targeted level of residual spherical aberration.
RESULTS: Fifty-seven men and 92 women were included (mean [±SD] age, 71.73 [±9.12] years). The RMS mean (±SD) values of Z4(0) were +0.353 (±0.132) μm, -0.121 (±0.034) μm, and +0.328 (±0.132) μm, respectively, for the anterior, posterior, and total cornea. The anterior, posterior, and total Z4(0) were on average significantly higher (p < 0.001) in women than in men. In both sexes, statistically significant (p < 0.05) age-related changes were found for the anterior and total Z4(0) but not for the posterior Z4(0) (p > 0.05). The total Z4(0) and total corneal refractive power were significantly correlated in men (p = 0.01) but not in women (p = 0.14). For postoperative targets of 0 ± 0.05/+0.10 ± 0.05 μm residual Z4(0), the proportion of eyes that would have qualified for implantation of negatively aspheric IOLs with -0.17 and with -0.27 μm was similar (61.1 and 56.3%, respectively; p = 0.09); significantly fewer eyes (6.7%) would have qualified for implantation of neutrally aspheric IOLs (p > 0.05).
CONCLUSIONS: Total corneal Z4(0) measured by Pentacam HR might be higher than that reported in previous studies. In most patients, the implantation of commercially available negatively aspheric IOLs would partially compensate for the positive total corneal Z4(0).

Entities:  

Mesh:

Year:  2014        PMID: 25192433     DOI: 10.1097/OPX.0000000000000380

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model.

Authors:  Tamer Tandogan; Gerd U Auffarth; Chul Y Choi; Stephanie Liebing; Christian Mayer; Ramin Khoramnia
Journal:  BMC Ophthalmol       Date:  2017-02-08       Impact factor: 2.209

2.  Distribution of corneal spherical aberration in a Tanzanian population.

Authors:  Hiroki Asano; Takahiro Hiraoka; Yusuke Seki; Teppei Shibata; Hiromi Osada; Takanori Saruta; Natsuko Hatsusaka; Fukumi Fujikake; Yoshiaki Tabata; Cellina Mhina; Anna Sanyiwa; Tetsuro Oshika; Hiroshi Sasaki
Journal:  PLoS One       Date:  2019-09-12       Impact factor: 3.240

3.  Effect of cataract incision type on corneal spherical aberration.

Authors:  Xiaochun Li; Xiaoguang Cao; Xian-Ru Hou; Li Yuan; Ying-Ying Yu; Yong-Zhen Bao
Journal:  Medicine (Baltimore)       Date:  2022-09-02       Impact factor: 1.817

4.  Distribution of corneal and ocular spherical aberrations in eyes with cataract in the Taiwanese population.

Authors:  Yung-Jen Lai; Shu-I Yeh; Huey-Chuan Cheng
Journal:  Taiwan J Ophthalmol       Date:  2015-05-12

5.  Prediction model for best focus, power, and spherical aberration of the cornea: Raytracing on a large dataset of OCT data.

Authors:  Achim Langenbucher; Nóra Szentmáry; Johannes Weisensee; Jascha Wendelstein; Alan Cayless; Rupert Menapace; Peter Hoffmann
Journal:  PLoS One       Date:  2021-02-22       Impact factor: 3.240

  5 in total