Literature DB >> 25191890

Prosthodontic maintenance of overdentures on zirconia implants: 1-year results of a randomized controlled trial.

Reham B Osman, Sunyoung Ma.   

Abstract

PURPOSE: The purpose of this study was to determine the prosthodontic outcomes of one-piece zirconia implants and their attachment systems in edentulous participants with maxillary and mandibular overdentures after 1 year of a randomized controlled trial.
MATERIALS AND METHODS: Random allocation of 24 edentulous participants (age range: 45 to 86 years) into titanium (control) or zirconia (test) groups using onepiece implants and a planned unsplinted prosthodontic design was performed. Four maxillary implants (one midpalatal; three anterior crestal) and three mandibular implants (one midsymphyseal; two bilateral distal) were conventionally loaded with the overdentures. Similar attachment systems were used throughout: ball abutment-type patrices (diameter: 2.25 to 3.1 mm as part of the one-piece implants) and custommade plastic matrices (with or without metal housings depending on the patrix size). Prosthodontic outcomes were documented during the first year of the clinical trial.
RESULTS: Following three deaths and two dropouts, there were 19 participants who were available at the 1-year recall. Of these participants, 3 had early maxillary implant failure and had to be converted to conventional maxillary complete dentures opposing mandibular implant overdentures. There were 79 maintenance events, 34 in the titanium (control) group and 45 in the zirconia (test) group. Patrix loss occurred as a result of three zirconia implant fractures (one mandibular and two crestal maxillary implants). Maintenance events were principally the replacement of matrices and overdenture fracture. Although relines and replacement overdentures also occurred, overall there were no significant differences in prosthodontic maintenance between the control and test groups. A six-field prosthodontic-success analysis table showed no statistically significant difference between the two groups; however, 50% of participants in each group were allocated to the retreatment (repair) field, which produced a low prosthodontic success rate.
CONCLUSIONS: Removable overdentures can be used on both one-piece titanium and zirconia implants with these attachment systems, due to no difference in prosthodontic maintenance and success. Before recommending routine use of a "metal-free" overdenture treatment option in clinical practice, consideration must be given to the success of the implants themselves.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25191890     DOI: 10.11607/ijp.3626

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  4 in total

Review 1.  Endosseous Dental Implant Materials and Clinical Outcomes of Different Alloys: A Systematic Review.

Authors:  Luca Fiorillo; Marco Cicciù; Tolga Fikret Tozum; Matteo Saccucci; Cristiano Orlando; Giovanni Luca Romano; Cesare D'Amico; Gabriele Cervino
Journal:  Materials (Basel)       Date:  2022-03-07       Impact factor: 3.623

2.  Zirconia versus Titanium Implants: 8-Year Follow-Up in a Patient Cohort Contrasted with Histological Evidence from a Preclinical Animal Model.

Authors:  Warwick J Duncan; Sunyoung Ma; Allauddin Siddiqi; Reham B Osman
Journal:  Materials (Basel)       Date:  2022-08-02       Impact factor: 3.748

3.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

4.  One-year prospective clinical study comparing patient satisfaction and masticatory performance of mandibular overdentures supported by one versus two implants.

Authors:  André Gustavo Paleari; Norberto Martins de Oliveira Junior; Danny Omar Mendoza Marin; Larissa Santana Rodriguez; João Neudenir Arioli Filho; Ana Carolina Pero; Marco Antonio Compagnoni
Journal:  J Appl Oral Sci       Date:  2018-10-04       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.