Literature DB >> 25191489

Upper third to lower third width ratio on chest x-ray may predict severity of obstruction in obstructive lung disease.

Ali Alavi Foumani1, Sahand Hamidi1, Maryam Shakiba1, Sara Massahnia1.   

Abstract

BACKGROUND: The symptoms and functional limitations due to obstructive lung disease (OLD) are the direct results of airway and lung parenchymal destruction. In these conditions, airflow obstruction leads to increased work of breathing, and gas exchange abnormalities. Hyperinflation, which is inferred from a standard chest radiograph (CXR), may imply increased total lung capacity that can be seen in patients with OLD. Based on experimental observations in OLD patients, we proposed that upper third width in posterioranterior (PA) CXR could be used as a rapid screening method for suggestion of OLD.
MATERIALS AND METHODS: In this cross-sectional study, 99 patients admitted to the Respiratory Ward of Razi Medical Center, a teaching referral hospital affiliated to Guilan University of Medical Sciences (GUMS), were entered in the study. The inclusion criteria were any FEV1 with FEV1/FVC <70% or FEV1/FVC>70% with MMEF 75/25 <65%. All cases with diagnostic possibilities other than OLD were excluded. The PA and lateral CXR were performed and 13 measurements - including previous well-known measurements and our proposed new ones- were made by an ordinary ruler on the films.
RESULTS: There was no significant correlation between the upper third width and superior/inferior (sup/inf) ratio with spirometric indices in patients. When considering only patients with FEV1/FVC <70%, middle third proportion width had a significant correlation with FEV1/FVC. In subgroup analysis when considering sup/inf ratio > 0.8, superior and inferior third widths were correlated with FEV1/FVC and when considering sup/inf ratio > 0.9, sup/inf ratio was significantly correlated with FEV1/FVC and FEV1.
CONCLUSION: The sup/inf ratio >0.9 in PA CXR, may be a predictor of obstructive pattern in OLD patients. For better correlation determination, larger and more extensive studies are needed.

Entities:  

Keywords:  Chest X-Ray; Obstructive Lung Disease; Severity

Year:  2014        PMID: 25191489      PMCID: PMC4153277     

Source DB:  PubMed          Journal:  Tanaffos        ISSN: 1735-0344


INTRODUCTION

Obstructive pulmonary diseases are a large group of disorders determined by airflow limitation. Airflow limitation frequently occurs because of abnormal inflammatory responses of the airways to many different materials leading to airways narrowing. These diseases include asthma, chronic obstructive pulmonary disease (COPD) and bronchiectasis (the most prevalent ones). Both asthma and COPD are widespread chronic lifetime diseases affecting patient’s quality of life and imposing high burdens on health organizations. Millions of people are suffering from asthma and COPD in the world. However, It seems that asthma and COPD are under-diagnosed because the symptoms and signs may not be sufficient for bringing the patients to medical centers or reaching a diagnosis by the physicians. Thus, we need diagnostic methods like spirometry to detect obstructive ventilatory defects. Permanent chronic airway obstruction may lead to hyperinflation. This condition, inferred from a standard chest radiograph (CXR), may be seen in COPD, asthma, bronchiectasis and bronchiolitis patients. However, CXR is not often considered a quantitative tool in routine practice but it seems that in some cases it can be (1). Hyperinflation on chest radiography is usually marked with lowered diaphragm (the diaphragm in the midclavicular line is at or blow the anterior end of the seventh rib), flattened diaphragm (determined by drawing a line between the costophrenic and cardiopherenic angles and the diaphragm height less than 1.5 cm), or increased retrosternal space (distance between the ascending aorta and the posterior sternum= 2.5-4.5 cm). Among these, the best indicator is the flattened diaphragm along with the concavity of the upper surface of the diaphragm. Another sign is increased width of the sternum; however, it has less sensitivity (2–4). Pulmonary function tests (PFT) and particularly spirometry are used for diagnosis, determining the severity of obstruction and tracking the disease progression (5, 6). There is an agreement with the correlation between radiographic findings obstruction indicators and spirometry (7–10). In posteroanterior film assessments in obstructive lung disease especially in the severe and long-term cases, we experimentally found that the ratio of lung width in upper third of lung length to the lung width in lower third tends towards one. The lung shape tends to change to a cylindrical or barrel shape. Therefore, this study was designed to assess the correlation between radiographic findings on PA films and spirometric obstruction indicators in patients with hyperinflation.

MATERIALS AND METHODS

This cross-sectional study was conducted on 99 patients admitted to the Respiratory Ward of Razi Medical Center (a teaching referral hospital affiliated to Guilan University of Medical Sciences) with spirometric data in favor of obstructive pattern: FEV1 /FVC(VC) <70 with any FEV1,or FEV1/FVC(VC) >70% with MMEF75/25 <65%; they did not have any other diseases. Posteroanterior and lateral chest radiographs were obtained by an analog radiography system and the measurements were made by an ordinary ruler (Figures 1,2).
Figure 1

Radiographic indices in Posteroanterior chest x ray

Figure 2

Radiographic indices in Lateral film.

Radiographic indices in Posteroanterior chest x ray Radiographic indices in Lateral film. Fourteen different radiographic measurements-including previous well-known measurements and our proposed new ones- were made on the films. Previous indices included: (A)– lung length, (B)- lung width at the level of right diaphragm, (C)- retrosternal space width, (D)– right diaphragm level on a PA film, (E)-right diaphragm level on a lateral film, (F)-lung width in upper third proportion of lung length, (G)-lung width in middle third proportion of lung length, (H)- lung width in lower third proportion of lung length, (I)- lung width at retrosternal width, (J)- Distance between parameter (B) and parameter (I). Our proposed indices included: (K)-The ratio of lung width in upper third proportion of lung length to lung width in middle third proportion of lung length, (L)- The ratio of lung width in middle third proportion of lung length to lung width in lower third proportion of lung length (M)-The ratio of lung width in upper third proportion of lung length to lung width in lower third proportion of lung length (N). All radiographic indices were recorded as in-to-in distance measurement in the chest. Standard spirometry was performed for all patients. The Research Vice-chancellorship of Guilan University of Medical Sciences (GUMS) approved and financially supported this study. Variables were reported as mean (SD) and valid and relative frequencies. Correlations between the radiographic measures and spirometric indices were analyzed by SPSS 19, using Pearson’s correlation method.

RESULTS

In correlation analysis with cut-off-point correlation ratio more than (r>04), a correlation was observed between lung length on a PA film and obstructive index of FEV1/FVC with r=-0.403. No correlation was observed between other conventional or newly proposed radiographic indices with spirometric indices according to Table 1. A correlation was detected only between some radiographic findings or proposed measurements and the spirometric results.
Table 1

Pearson’s coefficient in patients who underwent spirometry.

Radiographic indicesLung length in PA filmsLung width in PA filmsDiaphragm height in PA films
Lung width in upper third0.5800.712-
Lung width in middle third0.5470.711-
Lung width in lower third0.614-0.416
Distance between parameter B and I0.470--
Lung width in parameter E--0.531
Pearson’s coefficient in patients who underwent spirometry. The aim of this study was to assess the correlation between the proposed radiographic indices and the ratio of upper third to lower third lung width in PA films (indicating barreling or cylindrical shape of the chest) with obstructive pulmonary disease in spirometry. In order to determine the cut–off-point for the correlation of this index to obstructive indices in spirometry, only patients whose index N (sup/inf ratio) was more than 0.8 were entered in the second analysis. This way, 54 patients were eligible. After studying the results with r>04, significant correlations were found between the diaphragm height index on PA films with obstructive index of FEV1/FVC with r=-0.440, anteroposterior diameter of chest index on lateral films with FEV1/FVC with r =0.576 and proposed index of distance between index E and index C with FEV1 (r=-451). In the third analysis, only cases with index N(sup/inf ratio) greater than 0.9(sup/inf > 0.9) were studied. Eleven patients were eligible who underwent correlation analysis between spirometric and radiographic indices. Statistically, there was a significant correlation between conventional and proposed measurement with obstructive pulmonary indices in spirometry including MMEF75/25, FEV1 and FEV1/FVC (Table 2). There was a significant correlation between the conventional and newly proposed radiographic measurements (Table 3). There was no significant correlation between the index N (sup/inf ratio) and spirometric indices in patients. When considering only patients with FEV1/FVC <70%, middle third width had a significant correlation with FEV1/FVC. In subgroup analysis when considering index N (sup/inf ratio) > 0.8, superior and inferior third widths were correlated with FEV1/FVC and when considering index N(sup/inf ratio) > 0.9, sup/inf ratio was found to be significantly correlated with FEV1/FVC and FEV1.
Table 2

Pearson’s coefficient in patients with Sup/Inf ratio more than 0.9

Radiographic IndicesFEV1/FCVFEV1MMEF 75/25
Lung length in PA films--0.730
Lung width in PA films--0.660
Retrosternal width-0.5210.578
Diaphragm height in PA films-0.649-0.673
AP diameter-0.7390.663
Lung upper third width-0.620-
Lung middle third width-0.782-
Lung lower third width--0.768
Sup/inf-0.594-
Sup/mid--0.798
Mid/inf-0.594-
Distance between parameter B and I--0.4750.569
Lung width in parameter E-0.712-
Table 3

The Pearson’s correlation coefficient between old radiographic indices and proposed new radiographic indices only in patients with Sup/Inf ratio more than 0.9.

Radiographic IndicesLung length in PA filmsLung width in PA filmsAnteroposterior diameterRetrosternal widthDiaphragm height in PA filmsDiaphragm height in lateral films
Lung upper third width -0.4370.5820.533-0.462
Lung lower third width 0.4510.9010.6600.6520.6410.529
Sup/inf 0.460-0.5410.522---
Sup/mid -0.835-0.4570.494-
Mid/inf 0.459-0.5420.523---
Distance between parameter B and I 0.580-----
Lung width in parameter E --0.538--0.469
Pearson’s coefficient in patients with Sup/Inf ratio more than 0.9 The Pearson’s correlation coefficient between old radiographic indices and proposed new radiographic indices only in patients with Sup/Inf ratio more than 0.9.

DISCUSSION

In a study done by Dernaika and colleagues in 2005 in Oklahoma city (7), the predictability of the physiological impairment of pulmonary function test was assessed by CXR in COPD patients. Radiological evidence of emphysema was seen in 62% of patients. Flattening of the diaphragm (68%) was the most prevalent finding followed by bullous disease (59%) and increased retrosternal air space (46%). This study showed that CXR was an accurate predictive index for hyperinflation and the degree of functional impairment in COPD patients and a normal CXR obviates the need for pulmonary volume measurements. In our study, the flattening of diaphragm, as shown by diaphragm height reduction in PA and lateral chest films in the third (N:sup/inf ratio>0.8)and fourth analyses (N: sup/inf ratio>0.9) was correlated with spirometric indices (r=-0.669 and r=-0.440, respectively). In the fourth analysis, the height of diaphragm on the lateral film was only correlated with FEV1 (r=0.408). In addition, increased retrosternal space had a correlation with FEV1 after the fourth analysis (r=0.521). In a retrospective study done by Rothpearl and colleagues between 1980 and 1987 in New York city (8), the accuracy of radiological assessment of hyperinflation in 44 patients with emphysema and 39 control subjects and its correlation with ABG and PFT were assessed. The best indices that had a correlation, were pulmonary height, decreased diaphragmatic angle, total lung capacity (TLC) and heart size. In our study, no significant correlation was found between pulmonary height and spirometric indices in any analysis. We used height of diaphragm dome instead of angle, which was correlated with spirometric indices in the third and fourth analyses. Reich and his colleagues in their study in California in 1984 (10), showed that the quantitative changes of the right lung length in PA radiographs and the arc of the right diaphragm in lateral films (with or without adjustment for body surface area), and the level of the diaphragm relative to posterior ribs (when adjusted for body surface area) had the best correlation with abnormal PFT, showing that CXR can help the radiologist detect COPD. It may also be helpful in cases where clinical evaluation is not possible. In our study, we assessed the relative correlation between conventional and proposed CXR indices and spirometric data, and quantitative measurement correlations were not determined. In sub-analysis, the ratio of upper third to lower third width on PA radiographs (index N: sup/inf ratio>0.8 and >0.9) was correlatively assessed with conventional radiographic and spirometric indices and a correlation was observed between index N and obstructive spirometric indices with ratio >0.9. We proposed that N index (sup/inf ratio>0.9) in CXR could be a valuable parameter for detecting patients with obstructive lung disease. This index could be helpful as a rapid diagnostic tool for patients with obstructive lung disease when other evaluation methods are not available. Although this index correlated with an obstructive pattern, this study was performed on a small group of patients. Hence, a more comprehensive study with a larger sample size is needed in order to achieve high validity and assess the correlations in various cut-off-points.
  4 in total

1.  Radiographic measures of hyperinflation in clinical emphysema. Discrimination of patients from controls and relationship to physiologic and mechanical lung function.

Authors:  A Rothpearl; A O Varma; K Goodman
Journal:  Chest       Date:  1988-11       Impact factor: 9.410

2.  Chronic obstructive pulmonary disease: diagnostic considerations.

Authors:  Marvin Dewar; R Whit Curry
Journal:  Am Fam Physician       Date:  2006-02-15       Impact factor: 3.292

3.  Do radiographic criteria for emphysema predict physiologic impairment?

Authors:  K H Kilburn; R H Warshaw; J C Thornton
Journal:  Chest       Date:  1995-05       Impact factor: 9.410

4.  Correlation of radiographic measurements and pulmonary function tests in chronic obstructive pulmonary disease.

Authors:  S B Reich; A Weinshelbaum; J Yee
Journal:  AJR Am J Roentgenol       Date:  1985-04       Impact factor: 3.959

  4 in total
  1 in total

1.  Correlation of the Ratio of Upper Third to Lower Third Circumferences of the Chest with Obstructive Pattern in Spirometry.

Authors:  Ali Alavi Foumani; Azin Amin; Azita Tangestani Nejad; Ehsan Kazemnejad; Fatemeh Salamat; Sara Massahnia; Amir Hassankhani; Lida Khoshgozaran; Akram Mirfallah Nasiri; Mahsa Mohammadi
Journal:  Tanaffos       Date:  2015
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.