Literature DB >> 25189601

The first reported case of a retained epicardial pacing wire causing coronary artery compression and out-of-hospital cardiac arrest.

Ayyaz Sultan1, Javaid Iqbal1, David Hopkinson1, Anjan Siotia1, Ever D Grech2.   

Abstract

Entities:  

Mesh:

Year:  2014        PMID: 25189601     DOI: 10.1093/eurheartj/ehu308

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


× No keyword cloud information.
  1 in total

1.  Hemopericardium caused by a mobile retained epicardial pacing wire after ventricular septal defect repair: A case report.

Authors:  Li-Sheng Hsu; Jen-Te Hsu; Min-Lang Chen; Chien-Lin Liao
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889