Literature DB >> 25189097

Label-free and non-contact optical biosensing of glucose with quantum dots.

Saara A Khan1, Gennifer T Smith1, Felix Seo2, Audrey K Ellerbee1.   

Abstract

We present a label-free, optical sensor for biomedical applications based on changes in the visible photoluminescence (PL) of quantum dots in a thin polymer film. Using glucose as the target molecule, the screening of UV excitation due to pre-absorption by the product of an enzymatic assay leads to quenching of the PL of quantum dots (QDs) in a non-contact scheme. The irradiance changes in QD PL indicate quantitatively the level of glucose present. The non-contact nature of the assay prevents surface degradation of the QDs, which yields an efficient, waste-free, cost-effective, portable, and sustainable biosensor with attractive market features. The limit of detection of the demonstrated biosensor is ~3.5 µm, which is competitive with existing contact-based bioassays. In addition, the biosensor operates over the entire clinically relevant range of glucose concentrations of biological fluids including urine and whole blood. The comparable results achieved across a range of cost-affordable detectors, including a spectrophotometer, portable spectrometer, and iPhone camera, suggest that label-free and visible quantification of glucose with QD films can be applied to low-cost, point-of-care biomedical sensing as well as scientific applications in the laboratory for characterizing glucose or other analytes.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Glucose; Hexokinase–glucose 6-phosphate dehydrogenase; Optical transduction; Quantum dot

Mesh:

Substances:

Year:  2014        PMID: 25189097     DOI: 10.1016/j.bios.2014.08.035

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Metabolic Syndrome-An Emerging Constellation of Risk Factors: Electrochemical Detection Strategies.

Authors:  Madhurantakam Sasya; K S Shalini Devi; Jayanth K Babu; John Bosco Balaguru Rayappan; Uma Maheswari Krishnan
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

2.  A SPR biosensor based on signal amplification using antibody-QD conjugates for quantitative determination of multiple tumor markers.

Authors:  Huan Wang; Xiaomei Wang; Jue Wang; Weiling Fu; Chunyan Yao
Journal:  Sci Rep       Date:  2016-09-12       Impact factor: 4.379

3.  Effects of Surface Epitope Coverage on the Sensitivity of Displacement Assays that Employ Modified Nanoparticles: Using Bisphenol A as a Model Analyte.

Authors:  Yang Lu; Joshua Richard Peterson; Erwann Luais; John Justin Gooding; Nanju Alice Lee
Journal:  Biosensors (Basel)       Date:  2016-08-08
  3 in total