| Literature DB >> 25188322 |
Asa Holmner1, Kristie L Ebi2, Lutfan Lazuardi3, Maria Nilsson4.
Abstract
BACKGROUND: The healthcare sector is a significant contributor to global carbon emissions, in part due to extensive travelling by patients and health workers.Entities:
Mesh:
Year: 2014 PMID: 25188322 PMCID: PMC4154849 DOI: 10.1371/journal.pone.0105040
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Methods summary.
The study is based on the method used by Ong et al. that builds on existing LCA data for end-point devices used in videoconferencing and emission estimates for Internet traffic [17]. Completeness of the LCA data varies between devices, but includes energy costs and/or carbon emissions generated during manufacturing (M), distribution (D), operation (O) and end-of-life stages (E). Emissions data for MDE are provided in, or has been converted to, energy equivalents (kWh/unit) and is called embodied energy. Data for the videoconferencing solution (monitors, camera and video codecs) were modified to better fit our technological set-up. To obtain the hourly carbon cost of telerehabilitation in kgCO2e, we divided the embodied energy with estimates of the life length and use rates of all equipment, and applied a conversion factor of 0.6 kg CO2e/kWh [17], [20]. See also Equation 1.
Life cycle and operating costs of end point devices.
|
|
|
| |
|
| |||
| Desktop | 150 | 583 | M D O E |
| Laptop | 40 | 378 | M D O E |
| Camera | 9.5 | 33 | M D O E |
| Sound system | 4.1 | 104 | M O |
| Microphone | 2.5 | 52 | M O |
|
| |||
| 46” NEC LCD | 188 | 145 | M D O |
|
| |||
| Camera + codec (Cisco SX20) | 40 | 134 | M D O E |
| Local Area Network (LAN) end-points | 20 | 278 | M O |
* M = manufacturing, D = distribution, O = operation, E = end-of-life (disposal & recycle)
In the original reference, some values were converted from CO2e to MJ using a conversion factor of 0.6 kg CO2e/kWh [17], [20]. Data were further converted from MJ to kWh to better fit our calculations.
Embodied energy of the Cisco SX20 camera and codec was estimated from the embodied energy of camera and entry level video codec used in Ong et al. [17].
Data on the embodied energy of the NEC LCD monitor was based on an active screen size of 1018×572.7 mm and calculated from data provided by Ong et al. [17].
Estimates of the Internet opex and embodied energy.
| Maximum estimates | ||
| Bandwidth | Networking energy opex (kWh) | Embodied energy cost (kW) |
| 20 Mbit/s | 32 | 29.3 |
| 10 Mbit/s | 16 | 14.6 |
| 4 Mbit/s | 6.4 | 5.6 |
| 2 Mbit/s | 3.2 | 2.9 |
| 1 Mbit/s | 1.6 | 2.2 |
| 768 kbit/s | 1.2 | 1.5 |
| 512 kbit/s | 0.8 | 1.1 |
*For simplicity and to avoid underestimating the cost of Internet traffic, the network operating expenditure (opex) and embodied energy (in kWh) are based on the maximum estimate of the operating energy intensity (3.61 kWh/GB) and embodied energy (3.33 kWh/GB) of the Internet. To calculate the opex in kWh, the bandwidth was converted to bytes per hour (or MB/h).
Accumulated life cycle carbon costs of telemedicine versus face-to-face meetings.
| Speech therapy (481 visits) | Hand rehabilitation (238 visits) | |||
| kWh | kgCO2e | kWh | kgCO2e | |
|
| ||||
| Authentic conditions | 1004 | 602 | ||
| Lower bound | 741 | 409 | 305 | 183 |
| Upper bound | 3307 | 1984 | 818 | 1364 |
|
| ||||
| Travel by car (Lenzen) | 79 909 | 42 472 | ||
| Travel by car (Leduc) | 40 258 | 21 400 | ||
|
| ||||
| Authentic conditions | 1.4%/2.8% | |||
| Lower bound | 0.6%/1,0% | 0.4%/0.9% | ||
| Upper bound | 2.5%/4,9% | 3.2%/6.4% | ||
*Based on a conversion factor of 0.6 CO2e/kWh
Based on 157 connections to primary health centres using videoconferencing solutions and 81 connections to the patients home using desktop solutions. Such detailed data were not available in the speech therapy section.
Figure 2Summary of results.
Net emissions for the two scenarios. Hand and plastic surgery section (a), and speech therapy unit (b). Information on the technological set-up used for individual appointments was only available in the hand and plastic surgery section (actual). Therefore, we applied the upper and lower bound scenarios in the speech therapy clinic.
Figure 3Sensitivity analyses.
The analyses are based on the lower bound emissions scenario that emits 1.85 kgCO2e during a one hour meeting. All other factors were kept constant while changing the bandwidth (a), meeting duration (b) or use rates (c), respectively.