Literature DB >> 25186456

Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation.

François Jourda1, Rui Providencia1, Eloi Marijon2, Abdeslam Bouzeman1, Hassiba Hireche1, Ziad Khoueiry1, Christelle Cardin1, Nicolas Combes1, Stéphane Combes1, Serge Boveda1, Jean-Paul Albenque3.   

Abstract

AIMS: In the setting of paroxysmal atrial fibrillation (AF), there are no available data comparing the mid-term outcome of patients undergoing pulmonary vein isolation (PVI) catheter ablation using contact-force (CF)-guided radiofrequency (RF) vs. second-generation balloon cryotherapy. METHODS AND
RESULTS: Prospective single-centre evaluation, carried out from March 2011 to February 2013, comparing CF radiofrequency (Thermocool(®) SmartTouch™, Biosense Webster, Inc.) (CF group) with cryoballoon ablation (Arctic Front Advance™ 28 mm cryoballoon, Medtronic, Inc.) (CB group), in regards to procedural safety and efficacy, as well as recurrence at 12 months. Overall, 150 consecutive patients were enrolled (75 in each group). The characteristics of patients of both the groups were similar (61.2 ± 9.9 years, women 25.3%, mean AF duration 4.1 ± 4.0 years, mean CHA2DS2-VASc score 1.4 ± 1.3, mean HAS-BLED 1.4 ± 0.6). Duration of the procedure was significantly lower in the CF group (110.7 ± 32.5 vs. 134.5 ± 48.3 min, P = 0.001), with a lower duration of fluoroscopy (21.5 ± 8.5 vs. 25.3 ± 9.9 min, P = 0.017) and X-ray exposure (4748 ± 2411 cGy cm² vs. 7734 ± 5361 cGy cm², P = 0.001). In contrast, no significant difference was found regarding significant procedural complication (2.7 vs. 1.3% in CF and CB groups, respectively; P = 0.56), and PVI was eventually achieved in all cases. At 12 months, AF recurrence occurred in 11 patients (14.7%) in the CB group and in 9 patients (12.0%) in the CF group (HR = 1.20 95% CI 0.50-2.90; log rank P = 0.682).
CONCLUSIONS: Our preliminary findings suggest that CF-guided radiofrequency and cryotherapy present very similar performances in the setting of paroxysmal AF catheter ablation. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Contact-force; Cryoablation; Outcome

Mesh:

Year:  2014        PMID: 25186456     DOI: 10.1093/europace/euu215

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  41 in total

1.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation.

Authors:  Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane
Journal:  Heart Rhythm       Date:  2017-05-12       Impact factor: 6.343

Review 2.  Comparison of catheter ablation for paroxysmal atrial fibrillation between cryoballoon and radiofrequency: a meta-analysis.

Authors:  Chao-Feng Chen; Xiao-Fei Gao; Xu Duan; Bin Chen; Xiao-Hua Liu; Yi-Zhou Xu
Journal:  J Interv Card Electrophysiol       Date:  2017-01-07       Impact factor: 1.900

3.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Heart Rhythm       Date:  2012-03-01       Impact factor: 6.343

4.  Thermodynamic properties of atrial fibrillation cryoablation: a model-based approach to improve knowledge on energy delivery.

Authors:  Valter Giaretto; Andrea Ballatore; Claudio Passerone; Paolo Desalvo; Mario Matta; Andrea Saglietto; Mario De Salve; Fiorenzo Gaita; Bruno Panella; Matteo Anselmino
Journal:  J R Soc Interface       Date:  2019-09-18       Impact factor: 4.118

Review 5.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation.

Authors:  Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane
Journal:  Europace       Date:  2018-01-01       Impact factor: 5.214

6.  A long-term evaluation of cryoballoon ablation in 205 atrial fibrillation patients: a single center experience.

Authors:  Alexander Bohó; Silvia Mišíková; Peter Spurný; Erika Komanová; Michal Kerekanič; Marek Hudák; Branislav Stančák
Journal:  Wien Klin Wochenschr       Date:  2015-07-04       Impact factor: 1.704

Review 7.  [Radiofrequency current or cryoballoon for ablation of atrial fibrillation? : Hot or cold?]

Authors:  B Reissmann; K-H Kuck; A Metzner
Journal:  Herz       Date:  2017-06       Impact factor: 1.443

8.  Outcomes after cryoballoon or radiofrequency ablation for persistent atrial fibrillation: a multicentric propensity-score matched study.

Authors:  Serge Boveda; Rui Providência; Pascal Defaye; Dominique Pavin; Jean-Pierre Cebron; Frederic Anselme; Franck Halimi; Ziad Khoueiry; Nicolas Combes; Stephane Combes; Sophie Jacob; Jean-Paul Albenque; Pedro Sousa
Journal:  J Interv Card Electrophysiol       Date:  2016-05-18       Impact factor: 1.900

Review 9.  Making better scar: Emerging approaches for modifying mechanical and electrical properties following infarction and ablation.

Authors:  Jeffrey W Holmes; Zachary Laksman; Lior Gepstein
Journal:  Prog Biophys Mol Biol       Date:  2015-11-23       Impact factor: 3.667

10.  Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon.

Authors:  Alexander Pott; Kerstin Petscher; Marvin Messemer; Wolfgang Rottbauer; Tillman Dahme
Journal:  J Interv Card Electrophysiol       Date:  2016-07-23       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.