Noise pollution in the ICU: time to look into the mirror.

Koen S Simons, Munhum Park, Armin Kohlrausch, Mark van den Boogaard, Peter Pickkers, Werner de Bruijn, Cornelis P C de Jager.   

Abstract

Entities:  

Mesh:

Year:  2014        PMID: 25184539      PMCID: PMC4145538          DOI: 10.1186/s13054-014-0493-1

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
We read with interest the recent issue of Critical Care in which Darbyshire and Young [1] reported on noise levels in five different ICUs and demonstrated average sound pressure levels far above the World Health Organization recommended standard of 35 dB LAeq (A-weighted energy-equivalent sound pressure level in decibels). Although their article provides an interesting insight into the ICU soundscape, the authors did not attempt to investigate the sources of noise. In the literature, only few studies have performed an analysis of noise sources, using either questionnaires [2] or a human observer in the patient’s room [3-5]. Aiming to provide more insight into this matter, some of the authors recently performed an acoustic survey in an ICU room in order to determine which sources are responsible for the high noise levels, and details of this study were recently published [6]. Briefly, an audio recording was made by using a calibrated microphone in an ICU room at Jeroen Bosch Hospital for a duration of 67 hours. In addition to the analysis of various acoustic parameters, a 24-hour audio fragment was manually annotated by six research assistants. All sound events (n = 27,421) were identified by using 28 noise source labels, which were grouped into five noise categories. Acoustic analysis showed an average sound pressure level of 61 dB LAeq when the room was occupied. In agreement with the aforementioned study, the number of predicted loudness peaks was up to 90 per hour. Restorative periods were defined as periods of at least 5 minutes in which the sound pressure level relative to the background level did not exceed 17.7 dBA (A-weighted sound pressure level in decibels); only approximately 46% of the periods recorded at night were considered to be restorative, and the average duration of these restorative periods was approximately 13 minutes. Source-specific analysis revealed that, on average, noisy events related to staff activities (54 dB LAeq) occurred approximately 10 times per minute, staff speech (55 dB LAeq) occurred approximately 4 times per minute, and alarms (57 dB LAeq) also occurred approximately 4 times per minute. Further analyses showed that 57% of total acoustic energy and 92% of predicted loudness peaks could be attributed to the activities and speech of hospital personnel (Figure 1). We agree with Darbyshire and Young [1] that high sound pressure levels may have detrimental effects in the already vulnerable population of ICU patients. The aforementioned study demonstrates that more than half of all acoustic energy in an ICU is related to human activities and speech and therefore is potentially modifiable. Strategies involving the adaptation of human behavior therefore may prove to be very effective at reducing noise pollution in the ICU.
Figure 1

The contribution of each noise category for (A) the acoustic energy and (B) the number of predicted loudness peaks. Noise generated by or involving patients is excluded. For more details, refer to [6].

The contribution of each noise category for (A) the acoustic energy and (B) the number of predicted loudness peaks. Noise generated by or involving patients is excluded. For more details, refer to [6].
  6 in total

1.  Analysis of the soundscape in an intensive care unit based on the annotation of an audio recording.

Authors:  Munhum Park; Armin Kohlrausch; Werner de Bruijn; Peter de Jager; Koen Simons
Journal:  J Acoust Soc Am       Date:  2014-04       Impact factor: 1.840

2.  Patient perception of environmental and nursing factors contributing to sleep disturbances in a neurosurgical intensive care unit.

Authors:  Gülay Altun Uğraş; Seher Deniz Oztekin
Journal:  Tohoku J Exp Med       Date:  2007-07       Impact factor: 1.848

3.  Noise in acute patient care areas.

Authors:  B A Hilton
Journal:  Res Nurs Health       Date:  1985-09       Impact factor: 2.228

4.  Levels and sources of sound in the intensive care unit - an observational study of three room types.

Authors:  C Tegnestedt; A Günther; A Reichard; R Bjurström; J Alvarsson; C-R Martling; P Sackey
Journal:  Acta Anaesthesiol Scand       Date:  2013-06-10       Impact factor: 2.105

5.  Noise sources and levels in the Evgenidion Hospital intensive care unit.

Authors:  C Tsiou; D Eftymiatos; E Theodossopoulou; P Notis; K Kiriakou
Journal:  Intensive Care Med       Date:  1998-08       Impact factor: 17.440

6.  An investigation of sound levels on intensive care units with reference to the WHO guidelines.

Authors:  Julie L Darbyshire; J Duncan Young
Journal:  Crit Care       Date:  2013-09-03       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.