Literature DB >> 25181252

Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis.

Juan Pablo Gomez1, Fabio Marcelo Peña, Valentina Martínez, Diana C Giraldo, Carlos Iván Cardona.   

Abstract

OBJECTIVE: To describe, using a three-dimensional finite element (FE) model, the initial force system generated during bodily movement of upper canines with plastic aligners with and without composite attachments.
MATERIALS AND METHODS: A CAD model of an upper right canine, its alveolar bone and periodontal ligament, thermoformed plastic aligner, and two light-cured composite attachments were constructed. A FE model was used to analyze the effects of imposing a distal movement condition of 0.15 mm on the aligner (simulating the mechanics used to produce a distal bodily movement) with and without composite attachments.
RESULTS: In terms of tension and compression stress distribution, without composite attachments a compression area in the cervical third of the distal root surface and a tension area in the apical third of the mesial surface were observed. With composite attachments, uniform compression areas in the distal root surface and uniform tension area in the mesial root surface were observed. Compression areas in the active surfaces of the composite attachments were also observed. In terms of movement patterns, an uncontrolled distal inclination, with rotation axis between the middle and cervical root thirds, was observed without composite attachment. Distal bodily movement (translation) was observed with composite attachment.
CONCLUSIONS: In a three-dimensional FE analysis of a plastic aligner system biomechanically supplementary composite attachments generate the force system required to produce bodily tooth movement; the absence of biomechanically supplementary composite attachments favors the undesired inclination of the tooth during the translation movements.

Entities:  

Keywords:  Bodily movement; Finite element; Plastic aligners

Mesh:

Substances:

Year:  2014        PMID: 25181252      PMCID: PMC8612436          DOI: 10.2319/050714-330.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  15 in total

1.  A novel method for the three-dimensional (3-D) analysis of orthodontic tooth movement-calculation of rotation about and translation along the finite helical axis.

Authors:  Kazuo Hayashi; Yoshima Araki; Jun Uechi; Hiroki Ohno; Itaru Mizoguchi
Journal:  J Biomech       Date:  2002-01       Impact factor: 2.712

2.  Bodily labializing lateral incisors: 3D analysis using finite element method.

Authors:  Allahyar Geramy
Journal:  Acta Odontol Scand       Date:  2012-07-12       Impact factor: 2.331

3.  Torquing an upper central incisor with aligners--acting forces and biomechanical principles.

Authors:  Wolfram Hahn; Antonia Zapf; Henning Dathe; Julia Fialka-Fricke; Susanne Fricke-Zech; Rudolf Gruber; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Eur J Orthod       Date:  2010-05-12       Impact factor: 3.075

4.  Influence of force systems on archwire-bracket combinations.

Authors:  Robert P Kusy
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-03       Impact factor: 2.650

5.  The finite element method: a tool to study orthodontic tooth movement.

Authors:  P M Cattaneo; M Dalstra; B Melsen
Journal:  J Dent Res       Date:  2005-05       Impact factor: 6.116

6.  Mechanics of tooth movement.

Authors:  R J Smith; C J Burstone
Journal:  Am J Orthod       Date:  1984-04

7.  How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign.

Authors:  Neal D Kravitz; Budi Kusnoto; Ellen BeGole; Ales Obrez; Brent Agran
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-01       Impact factor: 2.650

8.  A nonlinear finite element analysis of the periodontal ligament under orthodontic tooth loading.

Authors:  Stephanie R Toms; Alan W Eberhardt
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-06       Impact factor: 2.650

9.  Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor.

Authors:  Wolfram Hahn; Benjamin Engelke; Klaus Jung; Henning Dathe; Julia Fialka-Fricke; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

10.  Effect of play between bracket and archwire on anterior tooth movement in sliding mechanics: A three-dimensional finite element study.

Authors:  Jun-Ya Tominaga; Pao-Chang Chiang; Hiroya Ozaki; Motohiro Tanaka; Yoshiyuki Koga; Christoph Bourauel; Noriaki Yoshida
Journal:  J Dent Biomech       Date:  2012-10-17
View more
  17 in total

1.  Clear aligner orthodontic therapy of rotated mandibular round-shaped teeth: A finite element study.

Authors:  Andrea Cortona; Gabriele Rossini; Simone Parrini; Andrea Deregibus; Tommaso Castroflorio
Journal:  Angle Orthod       Date:  2019-08-30       Impact factor: 2.079

2.  Bio-structural monitoring of bone mineral alterations through electromechanical impedance measurements of a Piezo-device joined to a tooth.

Authors:  Hector A Tinoco; Carlos I Cardona; Maribel L F Marín-Berrio; Juliana García-Grisales; Juan P Gomez; Samuel I Roldan; Fabio M Peña; Adam Brinek; Dominika Kalasová; Jozef Kaiser; Tomas Zikmund
Journal:  Biomed Eng Lett       Date:  2020-09-20

3.  Effect of in vitro aging by water immersion and thermocycling on the mechanical properties of PETG aligner material.

Authors:  Benjamin A Ihssen; Jan H Willmann; Amr Nimer; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2019-10-02       Impact factor: 1.938

4.  Adaptational changes in clear aligner fit with time.

Authors:  Amal I Linjawi; Amal M Abushal
Journal:  Angle Orthod       Date:  2022-03-01       Impact factor: 2.079

5.  Computer-aided finite element model for biomechanical analysis of orthodontic aligners.

Authors:  Tarek M Elshazly; Christoph Bourauel; Mostafa Aldesoki; Ahmed Ghoneima; Moosa Abuzayda; Wael Talaat; Sameh Talaat; Ludger Keilig
Journal:  Clin Oral Investig       Date:  2022-08-22       Impact factor: 3.606

6.  Comparative Assessment of Clinical and Predicted Treatment Outcomes of Clear Aligner Treatment: An in Vivo Study.

Authors:  Arisha Izhar; Gurkeerat Singh; Varun Goyal; Rajkumar Singh; Nishant Gupta; Prerna Pahuja
Journal:  Turk J Orthod       Date:  2019-12-01

7.  The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva.

Authors:  Biao Xiang; Xingxing Wang; Gang Wu; Yichen Xu; Menghan Wang; Yanjing Yang; Qingyu Wang
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

8.  Effects of Attachment of Plastic Aligner in Closing of Diastema of Maxillary Dentition by Finite Element Method.

Authors:  Yukiko Yokoi; Atsushi Arai; Jun Kawamura; Tomoko Uozumi; Yohei Usui; Norimasa Okafuji
Journal:  J Healthc Eng       Date:  2019-03-03       Impact factor: 2.682

9.  Biomechanical Effects of Different Auxiliary-Aligner Designs for the Extrusion of an Upper Central Incisor: A Finite Element Analysis.

Authors:  R Savignano; R Valentino; A V Razionale; A Michelotti; S Barone; V D'Antò
Journal:  J Healthc Eng       Date:  2019-08-07       Impact factor: 2.682

10.  Influence of Dental Composite Viscosity in Attachment Reproduction: An Experimental in Vitro Study.

Authors:  Vincenzo D'Antò; Simone Muraglie; Beatrice Castellano; Ettore Candida; Maria Francesca Sfondrini; Andrea Scribante; Cristina Grippaudo
Journal:  Materials (Basel)       Date:  2019-12-02       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.