Literature DB >> 25179717

Femoral non-elongating rodding in osteogenesis imperfecta - the importance of purchasing epiphyseal plate.

Wei-Chun Li, Hsuan-Kai Kao, Wen-E Yang, Chee-Jen Chang, Chia-Hsieh Chang1.   

Abstract

BACKGROUND: Corrective osteotomy and intramedullary rodding are widely used in children with osteogenesis imperfecta (OI), but revision rodding is often required. This study aims to investigate the effect of purchasing distal femoral epiphysis on the longevity of fixation using non-elongating rod.
METHODS: We investigated children with Sillence type III or IV OI who received antegrade femoral Rush rod fixations at age between 4 and 10 years in our institution. The fixations were classified into group A in which the rod reached distal femoral epiphysis and group B in which the rod stopped at femoral metaphysis. Failure of fixation is defined as rod cutting out of the cortex or when revision surgery was performed. Calculation of longevity of each rod fixation and Kaplan-Meier survival analysis were performed and compared between the two groups.
RESULTS: Eighteen children had the first femoral rodding at a mean age of 6.9 years and received a total of 61 femoral roddings with a mean follow-up of 11.4 years. Group A included 38 roddings performed at a mean age of 7.1 years and group B included 23 roddings performed at a mean age of 6.6 years. Group A had less revision rate (58% vs. 87%), more chance of survival > 3 years (74% vs. 43%), and longer median survival time (80 months vs. 33 months) than group B.
CONCLUSIONS: Less revision rate and better 3-year and 5-year survival rate were proved in the roddings that purchased epiphysis. We emphasize on using the precise implant length to purchase distal femoral epiphysis when non-elongating rod is the only available implant for fixation in children with OI.

Entities:  

Mesh:

Year:  2015        PMID: 25179717     DOI: 10.4103/2319-4170.137764

Source DB:  PubMed          Journal:  Biomed J        ISSN: 2319-4170            Impact factor:   4.910


  3 in total

1.  Combined technique of titanium telescopic rods and external fixation in osteogenesis imperfecta patients: First 12 consecutive cases.

Authors:  Dmitry Popkov; Tamara Dolganova; Eduard Mingazov; Dmitry Dolganov; Andrey Kobyzev
Journal:  J Orthop       Date:  2020-06-20

2.  Use of flexible intramedullary nailing in combination with an external fixator for a postoperative defect and pseudarthrosis of femur in a girl with osteogenesis imperfecta type VIII: a case report.

Authors:  Dmitry Popkov
Journal:  Strategies Trauma Limb Reconstr       Date:  2018-09-29

3.  Effects of a telescopic intramedullary rod for treating patients with osteogenesis imperfecta of the femur.

Authors:  D L Rosemberg; E O Goiano; M Akkari; C Santili
Journal:  J Child Orthop       Date:  2018-02-01       Impact factor: 1.548

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.