| Literature DB >> 25178005 |
Yuji Ohkubo1, Takashi Nakagawa1, Satoshi Seino1, Junichiro Kugai1, Takao A Yamamoto1, Hiroaki Nitani2, Yasuhiro Niwa2.
Abstract
Synchrotron X-ray-induced reduction of Au ions in an aqueous solution with or without support materials is reported. To clarify the process of radiation-induced reduction of metal ions in aqueous solutions in the presence of carbon particles as support materials, in situ time-resolved XANES measurements of Au ions were performed under synchrotron X-ray irradiation. XANES spectra were obtained only when hydrophobic carbon particles were added to the precursor solution containing Au ions. Changes in the shape of the XANES spectra indicated a rapid reduction from ionic to metallic Au in the precursor solution owing to synchrotron X-ray irradiation. In addition, the effects of the wettability of the carbon particles on the deposited Au metallic spots were examined. The deposited Au metallic spots were different depending on the relationship of surface charges between metal precursors and support materials. Moreover, a Au film was obtained as a by-product only when hydrophilic carbon particles were added to the precursor solution containing the Au ions.Entities:
Keywords: Au-LIII edge; X-ray absorption near-edge structure (XANES); radiation-induced reduction; synchrotron X-rays
Year: 2014 PMID: 25178005 PMCID: PMC4333730 DOI: 10.1107/S1600577514012703
Source DB: PubMed Journal: J Synchrotron Radiat ISSN: 0909-0495 Impact factor: 2.616
List of previously reported research papers and unreported conditions on X-ray-induced reduction and in situ measurement
| Paper ID | Year | Phase | Metal species | Support material | X-ray source |
|
|---|---|---|---|---|---|---|
| Reference 1 | 2005 | Solid | Monometal (Au) | No | XPS | XPS |
| Reference 2 | 2007 | Solid | Bimetal (AuPt) | No | XPS | XPS |
| Reference 3 | 2011 | Solid | Monometal (Au) | No | Synchrotron X-ray | XPS |
| Reference 4 | 2001 | Liquid | Monometal (Cu) | No | Synchrotron X-ray | XAFS |
| Reference 5 | 2005 | Liquid | Monometal (Cu) | No | Synchrotron X-ray | XAFS and UVVis |
| Reference 6 | 2006 | Liquid | Monometal (Cu) | No | Synchrotron X-ray | XAFS and UVVis |
| Reference 7 | 2012 | Liquid | Monometal (Fe) | No | Synchrotron X-ray | XAFS |
| Reference 8 | 2013 | Liquid | Monometal (Au) | No | Synchrotron X-ray | XAFS |
| Unreported conditions I | Liquid | Bimetal | No | Synchrotron X-ray | XAFS | |
| Unreported conditions II | Liquid | Monometal | Yes | Synchrotron X-ray | XAFS | |
| Unreported conditions III | Liquid | Bimetal | Yes | Synchrotron X-ray | XAFS |
Figure 1Schematic of the irradiation with synchrotron X-rays and in situ time-resolved XANES measurements of Au ions in the aqueous solution.
Sample IDs and experimental conditions of the precursor solution and irradiation with synchrotron X-rays
| Sample ID | Input Au concentration [mM] | Solution volume [mL] | Dispersed support material | Gap distance [mm] | Irradiated beam width [mm] | Irradiation time [min] |
|---|---|---|---|---|---|---|
| Sample 1 | 80 | 1.6 | No support | 24 | 25 | 24 |
| Sample 2 | 80 | 1.6 | No support | 32 | 25 | 20 |
| Sample 3 | 80 | 1.6 | Hydrophobic carbon | 32 | 10 | 22 |
| Sample 4 | 80 | 1.6 | Hydrophilic carbon | 32 | 10 | 10 |
Deposited Au metallic spots for samples 14 and analyzability of time-resolved XANES spectra
| Sample ID | On the PI film | On the acrylic cell | On the support material | XANES spectra |
|---|---|---|---|---|
| Sample 1 | Yes | No | No support | Unanalyzable |
| Sample 2 | Yes | No | No support | Unanalyzable |
| Sample 3 | No | No | Yes | Analyzable |
| Sample 4 | Yes | Yes | N/A | Unanalyzable |
Figure 2Photographs [(a)–(c), (e)–(f)] and TEM (d) image of metallic Au deposited via synchrotron X-ray irradiation: (a) PI film for sample 1, (b) PI film for sample 2, (c) PI film for sample 3, (d) carbon particles for sample 3, (e) PI film for sample 4, (f) acrylic cell for sample 4.
Figure 3In situ time-resolved XANES spectra around the Au-L III edge obtained for sample 3 during the synchrotron X-ray-induced reduction of Au ions in the aqueous solution.
Figure 4Ratios of HAuCl4 and metallic Au calculated using in situ time-resolved XANES spectra in Fig. 3 ▶ by linear-combination fitting.