OBJECTIVES: In the emergency department (ED), intravenous (IV) catheter placement is one of the most frequent interventions and may be a real challenge in some conditions. Improvement of the success rate with new technology represents a great opportunity. This randomized controlled trial aimed to show the superiority of AccuVein to cannulate veins in adults compared to routine care.
METHODS: After giving written consent, patients were randomized into two groups: routine IV catheter insertion or insertion guided by the AccuVein, which is a hand-held instrument displaying laser light to optimize visualization of veins. The primary outcome was the time to successful placement of catheters. Secondary outcomes included the number of attempts, the rate of failure, technique-related pain, occurrence of movements, and efficiency of IV cannulation as perceived by the operator when using the AccuVein device. Results are given as mean and bootstrapped 95% confidence interval (CI) and percentages. p-values of <0.05 were considered significant.
RESULTS: A total of 266 six patients were included, with 157 randomized to routine cannulation and 115 to AccuVein. Patient characteristics were similar. Time to successful placement of IV catheter (routine, 98 seconds, 95% CI = 85 to 113 seconds; and AccuVein, 119 seconds, 95% CI = 93 to 154 seconds) was not different between groups (p = 0.24). Secondary outcomes (failure and pain) did not significantly differ, except for movements, which were more frequent when using the AccuVein device (19.1% vs. 10.2%, p = 0.05). Evaluation of the AccuVein by operators was more often negative than positive.
CONCLUSIONS: Use of the AccuVein did not improve IV cannulation in nonselected ED patients.
© 2014 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Year:  2014        PMID: 25176152     DOI: 10.1111/acem.12437

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  5 in total

1.  Use of vein-viewing device to assist intravenous cannulation decreases the time and number of attempts for successful cannulation in pediatric patients.

Authors:  Alka Sara Saju; Lilly Prasad; Menaka Reghuraman; Immanuel Karl Sampath
Journal:  Paediatr Neonatal Pain       Date:  2019-10-31

2.  Development of a clinical prediction rule to improve peripheral intravenous cannulae first attempt success in the emergency department and reduce post insertion failure rates: the Vascular Access Decisions in the Emergency Room (VADER) study protocol.

Authors:  Peter J Carr; James C R Rippey; Marie L Cooke; Chrianna Bharat; Kevin Murray; Niall S Higgins; Aileen Foale; Claire M Rickard
Journal:  BMJ Open       Date:  2016-02-11       Impact factor: 2.692

3.  Initial experience with use of infrared assistance for intravenous injection of radiopharmaceuticals.

Authors:  Ashok Kumar; Meena Negi; Jyoti Khanka; Mohit Dhingra; Ranjeeta Kumari; Vandana Kumar Dhingra; Manoj Kumar Gupta
Journal:  World J Nucl Med       Date:  2020-10-02

4.  Non-Invasive Imaging of Preoperative Mapping of Superficial Veins in Free Flap Breast Reconstruction.

Authors:  Michael W Chu; Jonathon R Sarik; Liza C Wu; Joseph M Serletti; Jonathan Bank
Journal:  Arch Plast Surg       Date:  2016-01-15

5.  A Novel Smart Assistance System for Blood Vessel Approaching: A Technical Report Based on Oximetry.

Authors:  Chien-Ching Lee; Chia-Chun Chuang; Bo-Cheng Lai; Yi-Chia Huang; Jen-Yin Chen; Bor-Shyh Lin
Journal:  Sensors (Basel)       Date:  2020-03-29       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.