Literature DB >> 25175693

True Reproducibility of UltraSound Techniques (TRUST): systematic review of reliability studies in obstetrics and gynecology.

M A Coelho Neto1, P Roncato1,2, C O Nastri1, W P Martins1.   

Abstract

OBJECTIVES: To examine the quality of methods used and the accuracy of the interpretation of agreement in existing studies that examine the reliability of ultrasound measurements and judgments in obstetrics and gynecology.
METHODS: A systematic search of MEDLINE was performed on 25 March 2014, looking for studies that examined the reliability of ultrasound measurements and judgments in obstetrics and gynecology with evaluation of concordance (CCC) or intraclass (ICC) correlation coefficients or kappa as a main objective.
RESULTS: Seven hundred and thirty-three records were examined on the basis of their title and abstract, of which 141 full-text articles were examined completely for eligibility. We excluded 29 studies because they did not report CCC/ICC/kappa, leaving 112 studies that were included in our analysis. Two studies reported both ICC and kappa and were counted twice, therefore, the number used as the denominator in the analyses was 114. Only 16/114 (14.0%) studies were considered to be well designed (independent acquisition and blinded analysis) and to have interpreted the results properly. Most errors occurring in the studies are likely to overestimate the reliability of the method examined.
CONCLUSIONS: The vast majority of published studies examined had important flaws in design, interpretation and/or reporting. Such limitations are important to identify as they might create false confidence in the existing measurements and judgments, jeopardizing clinical practice and future research. Specific guidelines aimed at improving the quality of reproducibility studies that examine ultrasound methods should be encouraged.
Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

Keywords:  gynecology; obstetrics; reproducibility of results; ultrasound

Mesh:

Year:  2015        PMID: 25175693     DOI: 10.1002/uog.14654

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

1.  Fetal renal artery blood flow - Normal ranges.

Authors:  Sonja Brennan; David Watson; Michal Schneider; Donna Rudd; Yogavijayan Kandasamy
Journal:  Ultrasound       Date:  2021-06-15

2.  A comparison of ultrasound with magnetic resonance imaging in the assessment of fetal biometry and weight in the second trimester of pregnancy: An observer agreement and variability study.

Authors:  Jacqueline Matthew; Christina Malamateniou; Caroline L Knight; Kelly P Baruteau; Tara Fletcher; Alice Davidson; Laura McCabe; Dharmintra Pasupathy; Mary Rutherford
Journal:  Ultrasound       Date:  2018-01-29

3.  Optimization of Fetal Biometry With 3D Ultrasound and Image Recognition (EPICEA): protocol for a prospective cross-sectional study.

Authors:  Gaëlle Ambroise Grandjean; Gabriela Hossu; Claire Banasiak; Cybele Ciofolo-Veit; Caroline Raynaud; Laurence Rouet; Olivier Morel; Marine Beaumont
Journal:  BMJ Open       Date:  2019-12-15       Impact factor: 2.692

4.  A decision support system based on radiomics and machine learning to predict the risk of malignancy of ovarian masses from transvaginal ultrasonography and serum CA-125.

Authors:  Valentina Chiappa; Matteo Interlenghi; Giorgio Bogani; Christian Salvatore; Francesca Bertolina; Giuseppe Sarpietro; Mauro Signorelli; Dominique Ronzulli; Isabella Castiglioni; Francesco Raspagliesi
Journal:  Eur Radiol Exp       Date:  2021-07-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.