Literature DB >> 25175270

Influence of posterior corneal astigmatism on total corneal astigmatism in eyes with moderate to high astigmatism.

Giacomo Savini1, Francesco Versaci2, Gabriele Vestri2, Pietro Ducoli2, Kristian Næser2.   

Abstract

PURPOSE: To evaluate the influence of posterior corneal astigmatism on total corneal astigmatism in patients with 1.00 diopter (D) or more of corneal astigmatism.
SETTING: Private practice, Bologna, Italy.
DESIGN: Prospective case series.
METHODS: Corneal astigmatism was measured using a Scheimpflug camera combined with a corneal topographer (Sirius). Keratometric astigmatism, anterior corneal astigmatism, posterior corneal astigmatism, and total corneal astigmatism were evaluated. Vector analysis was performed according to the Næser method.
RESULTS: One hundred fifty-seven eyes were enrolled. Keratometric astigmatism was with the rule (WTR), against the rule (ATR), and oblique in 84.0%, 11.5%, and 4.5% of eyes, respectively. Posterior corneal astigmatism exceeded 0.50 D and 1.00 D in 55.4% of eyes and 5.7% of eyes, respectively. The mean posterior corneal astigmatism was 0.54 D, inclined 91 degrees in relation to the steeper anterior corneal meridian. The steepest meridian was vertically aligned in 93.0% of cases. Compared with total corneal astigmatism, keratometric astigmatism overestimated WTR astigmatism by a mean of 0.22 D ± 0.32 (SD), underestimated ATR astigmatism by 0.21 ± 0.26 D, and overestimated oblique astigmatism by 0.13 ± 0.37 D. In the whole sample, a difference in astigmatism magnitude of 0.50 D or more was detected between keratometric astigmatism and total corneal astigmatism in 16.6% of cases and the difference in the location of the steep meridian was greater than 10 degrees in 3.8% of cases.
CONCLUSION: In patients who are candidates for surgical correction of astigmatism, measuring only the anterior corneal curvature can lead to inaccurate evaluation of the total corneal astigmatism. FINANCIAL DISCLOSURE: Mr. Versaci and Mr. Vestri are employees of Costruzione Strumenti Oftalmici Srl. No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25175270     DOI: 10.1016/j.jcrs.2014.01.046

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  21 in total

1.  Distribution of the anterior, posterior, and total corneal astigmatism in healthy eyes.

Authors:  Sepehr Feizi; Mohammad Naderan; Vahid Ownagh; Fatemeh Sadeghpour
Journal:  Int Ophthalmol       Date:  2017-03-13       Impact factor: 2.031

2.  Effect of femtosecond laser-assisted steepest-meridian clear corneal incisions on preexisting corneal regular astigmatism at the time of cataract surgery.

Authors:  Wei Chen; Min Ji; Jian Wu; Yong Wang; Jing Zhou; Rong-Rong Zhu; Hong Lu; Huai-Jin Guan
Journal:  Int J Ophthalmol       Date:  2020-12-18       Impact factor: 1.779

3.  Effect of the posterior corneal surface on total corneal astigmatism in patients with age-related cataract.

Authors:  Ying-Ying Jin; Zhen Zhou; Xiao-Yong Yuan; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

Review 4.  Spotlight on the Corneal Back Surface Astigmatism: A Review.

Authors:  Sudi Patel; Larysa Tutchenko
Journal:  Clin Ophthalmol       Date:  2021-07-26

5.  Distribution of posterior corneal astigmatism and aberration before cataract surgery in Chinese patients.

Authors:  Yongxiang Jiang; Yating Tang; Qinghe Jing; Dongjin Qian; Yi Lu
Journal:  Eye (Lond)       Date:  2018-08-13       Impact factor: 3.775

6.  Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging.

Authors:  Giacomo Savini; Leonardo Taroni; Domenico Schiano-Lomoriello; Kenneth J Hoffer
Journal:  Eye (Lond)       Date:  2020-11-02       Impact factor: 4.456

7.  Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power.

Authors:  James A Davison; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-08-19

8.  Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2016-11-03

9.  Polar Value Analysis of Low to Moderate Astigmatism with Wavefront-Guided Sub-Bowman Keratomileusis.

Authors:  Pisong Yan; Zhiyu Du; Yu Zhang
Journal:  J Ophthalmol       Date:  2017-08-02       Impact factor: 1.909

10.  The Effect of the Degree of Astigmatism on Optical Quality in Children.

Authors:  Jing Gao; Xiao-Xia Wang; Lin Wang; Yuan Sun; Rui-Fen Liu; Qi Zhao
Journal:  J Ophthalmol       Date:  2017-06-01       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.