Literature DB >> 25174535

Effect of the number of suture throws on the biomechanical characteristics of the suture-tendon construct.

Chih-Kai Hong1, Cheng-Li Lin2, Chih-Hsun Chang1, I-Ming Jou2, Wei-Ren Su3.   

Abstract

PURPOSE: We aimed to investigate the effect of the number of suture throws on biomechanical characteristics of the suture-tendon construct for 3 currently used suture configurations in this ex vivo biomechanical study.
METHODS: Three stitch configurations-the Krackow stitch, the locking SpeedWhip (LSW) stitch, and the modified finger trap (MFT) suture-were assessed with 3, 5, and 7 throws using porcine flexor profundus tendons randomly divided into 9 groups of 11 specimens. The Krackow stitch and MFT suture were completed with nonabsorbable No. 2 braided sutures, whereas the LSW stitch was completed with loops of nonabsorbable No. 2 braided sutures. Each tendon was pretensioned to 100 N for 3 cycles and then cyclically loaded to 200 N for 200 cycles. Finally, each tendon was loaded to failure. Percent elongation, load to failure, and mode of failure for each suture-tendon construct were measured.
RESULTS: After being pretensioned, there were no significant differences in the elongation between different suture throws in the LSW and MFT suture groups (P = .38 and P = .34, respectively). The elongation of the Krackow 7-throw suture group was significantly greater than that of the 5-throw (P = .01) and 3-throw groups (P = .03). After cyclic loading, there was no significant difference in the elongation of each suture technique with respect to different suture throws. The elongation after 200 loading cycles of the MFT sutures was significantly less than that of the Krackow and LSW sutures for all throws. The load to failure and cross-sectional area (43.1 ± 4.6 mm(2); P = .398) were not significantly different across all groups.
CONCLUSIONS: This ex vivo biomechanical study showed that there are no significant differences in elongation after cyclic loading and load to failure among the various suture throws for the 3 types of sutures investigated. CLINICAL RELEVANCE: The 3-suture throw configuration may provide sufficient fixation of the tendon graft regarding biomechanical characteristics of elongation and load to failure in the clinical setting of tendon docking without interference screw fixation.
Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2014        PMID: 25174535     DOI: 10.1016/j.arthro.2014.06.029

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  8 in total

1.  Mini-open incision for distal biceps repair by suture anchors: follow-up of eighteen patients.

Authors:  L Pangallo; A Valore; L Padovani; G Coratella; F Schena; B Magnan; R Adani
Journal:  Musculoskelet Surg       Date:  2015-04-23

2.  Do Needleless Knots have Similar Strength as the Krackow Suture? An In Vitro Porcine Tendon Study.

Authors:  Chih-Kai Hong; Ting-Hsuan Kuo; Ming-Long Yeh; I-Ming Jou; Cheng-Li Lin; Wei-Ren Su
Journal:  Clin Orthop Relat Res       Date:  2016-11-07       Impact factor: 4.176

3.  Surgical time for graft preparation using different suture techniques.

Authors:  Lawrence Camarda; Sebastian Giambartino; Michele Lauria; Michele Saporito; Vito Triolo; Michele D'Arienzo
Journal:  Muscles Ligaments Tendons J       Date:  2016-09-17

4.  The buried knot technique for all inside graft link preparation leads to superior biomechanical graft link stability.

Authors:  Thomas M Tiefenboeck; Lena Hirtler; Markus Winnisch; Harald Binder; Thomas Koch; Micha Komjati; Marcus Hofbauer; Roman C Ostermann
Journal:  Sci Rep       Date:  2019-02-06       Impact factor: 4.379

5.  The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.

Authors:  Jan Theopold; Stefan Schleifenbaum; Alexander Georgi; Michael Schmidt; Ralf Henkelmann; Georg Osterhoff; Pierre Hepp
Journal:  Arch Orthop Trauma Surg       Date:  2020-01-24       Impact factor: 3.067

6.  The Biomechanical Properties of a High-Tensile Strength Tape for Tendon Graft Fixation Using the Krackow Configuration.

Authors:  Chih-Kai Hong; Kai-Lan Hsu; Fa-Chuan Kuan; Yueh Chen; Chen-Hao Chiang; Ming-Long Yeh; Miin-Jye Wen; Wei-Ren Su
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-07-09

7.  Biomechanical Comparison of a Novel Multiplanar, Perpendicular Whipstitch With the Krackow Stitch and Standard Commercial Whipstitch.

Authors:  Stefano Muscatelli; Kempland C Walley; Conor S Daly-Seiler; Joseph A Greenstein; Aaron Sciascia; David P Patterson; Michael T Freehill
Journal:  Orthop J Sports Med       Date:  2022-08-12

8.  Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope™.

Authors:  Takahisa Sasho; Toshihide Sasaki; Hiroko Hoshi; Ryuichiro Akagi; Takahiro Enomoto; Yusuke Sato; Ryosuke Nakagawa; Masamichi Tahara; Satoshi Yamaguchi
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2018-03-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.