Literature DB >> 25170001

The relationship between various parameters of complete denture quality and patients' satisfaction.

Sara A Alfadda1.   

Abstract

BACKGROUND: Patients' appreciation of their conventional complete dentures might be affected by the quality of the dentures.
METHODS: A random sample of 33 edentulous patients who were rehabilitated by means of conventional complete dentures participated in the study. Three independent investigators who underwent technique calibration evaluated the dentures on the basis of seven clinical criteria by using a validated examination form. The patients filled out a validated denture satisfaction scale. The author used Pearson product-moment correlation and analysis of covariance to identify possible correlations.
RESULTS: The study results showed that most patients were between "reasonably satisfied" and "very satisfied" with their dentures. The author found nominally higher satisfaction among those receiving both mandibular and maxillary dentures and significant positive correlations between the overall denture satisfaction score and the stability of the mandibular denture (P = .039) and retention of the mandibular denture (P = .005). In contrast, esthetic lip support and lower lip line, occlusion, and maxillary stability and retention were not correlated with participants' overall satisfaction level (P > .064).
CONCLUSIONS: The results of this study show that a clinically stable mandibular denture was the most important determinant of patients' satisfaction. PRACTICAL IMPLICATIONS: The study findings highlight the most important denture quality parameters that can aid clinicians in meeting their patients' expectations.

Entities:  

Keywords:  Complete dentures; mandibular; maxillary; patient satisfaction; retention; stability

Mesh:

Year:  2014        PMID: 25170001     DOI: 10.14219/jada.2013.48

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  7 in total

Review 1.  Unsplinted Attachments and Patient-Reported Outcome Measures (PROMs) in 2-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Ting Jing Kweh; Smita Nimbalkar
Journal:  Int J Dent       Date:  2022-05-24

2.  Design and fabrication of complete dentures using CAD/CAM technology.

Authors:  Weili Han; Yanfeng Li; Yue Zhang; Yuan Lv; Ying Zhang; Ping Hu; Huanyue Liu; Zheng Ma; Yi Shen
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

3.  Evaluation of Satisfaction Perceived by Prosthetic Patients Compared to Clinical and Technical Variables.

Authors:  Ettore Epifania; Roberto Sanzullo; Roberto Sorrentino; Pietro Ausiello
Journal:  J Int Soc Prev Community Dent       Date:  2018-05-17

Review 4.  Maintaining occlusal stability by selecting the most appropriate occlusal scheme in complete removable prosthesis.

Authors:  Sara Sabir; Anissa Regragui; Nadia Merzouk
Journal:  Jpn Dent Sci Rev       Date:  2019-11-05

5.  Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial.

Authors:  Pravinkumar G Patil; Liang Lin Seow
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

6.  Effect of Implant Positions and Angulations on Retentive Strength of 2-Implant Mandibular Overdentures: An In Vitro Study with the New 3D-Printed Simulation Method.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Rashmi Uddanwadikar; Allan Pau; Piyush D Ukey
Journal:  Int J Dent       Date:  2022-09-14

7.  Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers.

Authors:  Yuri Martins Costa; André Luís Porporatti; Priscila Brenner Hilgenberg-Sydney; Leonardo Rigoldi Bonjardim; Paulo César Rodrigues Conti
Journal:  J Appl Oral Sci       Date:  2015 Nov-Dec       Impact factor: 2.698

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.