AIMS: We sought to compare the diagnostic accuracy of basal stenosis resistance index (BSR), instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) for stenosis-specific myocardial ischaemia identified by means of a combined reference standard of myocardial perfusion scintigraphy and the hyperaemic stenosis resistance index. METHODS AND RESULTS: BSR and FFR were determined for 299 coronary stenoses, iFR was determined for 85 coronary stenoses (iFR cohort). The discriminative value for stenosis-specific myocardial ischaemia was compared by means of the area under the receiver operating characteristic (ROC) curves (AUC). Classification agreement with the reference standard was determined according to ROC curve-derived ischaemic cut-off values, as well as according to clinical cut-off values, equivalent to the 0.80 FFR cut-off. Across all stenoses, the discriminative value of BSR and FFR was equivalent (AUC: 0.90 and 0.91, respectively, p=0.46). In the iFR cohort, the discriminative value was equivalent for BSR, iFR, and FFR (AUC: 0.88, 0.84, and 0.88, respectively; p≥0.20 for all). At both ischaemic as well as clinical cut-off values, classification agreement with the reference standard was equivalent for BSR and FFR across all stenoses, as well as for BSR, iFR, and FFR in the iFR cohort. CONCLUSIONS: BSR, iFR, and FFR have equivalent diagnostic accuracy for the detection of ischaemia-generating coronary stenoses.
AIMS: We sought to compare the diagnostic accuracy of basal stenosis resistance index (BSR), instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) for stenosis-specific myocardial ischaemia identified by means of a combined reference standard of myocardial perfusion scintigraphy and the hyperaemic stenosis resistance index. METHODS AND RESULTS: BSR and FFR were determined for 299 coronary stenoses, iFR was determined for 85 coronary stenoses (iFR cohort). The discriminative value for stenosis-specific myocardial ischaemia was compared by means of the area under the receiver operating characteristic (ROC) curves (AUC). Classification agreement with the reference standard was determined according to ROC curve-derived ischaemic cut-off values, as well as according to clinical cut-off values, equivalent to the 0.80 FFR cut-off. Across all stenoses, the discriminative value of BSR and FFR was equivalent (AUC: 0.90 and 0.91, respectively, p=0.46). In the iFR cohort, the discriminative value was equivalent for BSR, iFR, and FFR (AUC: 0.88, 0.84, and 0.88, respectively; p≥0.20 for all). At both ischaemic as well as clinical cut-off values, classification agreement with the reference standard was equivalent for BSR and FFR across all stenoses, as well as for BSR, iFR, and FFR in the iFR cohort. CONCLUSIONS: BSR, iFR, and FFR have equivalent diagnostic accuracy for the detection of ischaemia-generating coronary stenoses.
Authors: Tim P van de Hoef; Joo Myung Lee; Mauro Echavarria-Pinto; Bon-Kwon Koo; Hitoshi Matsuo; Manesh R Patel; Justin E Davies; Javier Escaned; Jan J Piek Journal: Nat Rev Cardiol Date: 2020-05-14 Impact factor: 32.419
Authors: Ricardo Petraco; Rasha Al-Lamee; Matthias Gotberg; Andrew Sharp; Farrel Hellig; Sukhjinder S Nijjer; Mauro Echavarria-Pinto; Tim P van de Hoef; Sayan Sen; Nobuhiro Tanaka; Eric Van Belle; Waldemar Bojara; Kunihiro Sakoda; Martin Mates; Ciro Indolfi; Salvatore De Rosa; Christian J Vrints; Steven Haine; Hiroyoshi Yokoi; Flavio L Ribichini; Martjin Meuwissen; Hitoshi Matsuo; Luc Janssens; Ueno Katsumi; Carlo Di Mario; Javier Escaned; Jan Piek; Justin E Davies Journal: Am Heart J Date: 2014-07-21 Impact factor: 4.749