Literature DB >> 25167150

High-frame-rate 2-D vector blood flow imaging in the frequency domain.

Matteo Lenge, Alessandro Ramalli, Enrico Boni, Hervé Liebgott, Christian Cachard, Piero Tortoli.   

Abstract

Conventional ultrasound Doppler techniques estimate the blood velocity exclusively in the axial direction to produce the sonograms and color flow maps needed for diagnosis of cardiovascular diseases. In this paper, a novel method to produce bi-dimensional maps of 2-D velocity vectors is proposed. The region of interest (ROI) is illuminated by plane waves transmitted at the pulse repetition frequency (PRF) in a fixed direction. For each transmitted plane wave, the backscattered echoes are recombined offline to produce the radio-frequency image of the ROI. The local 2-D phase shifts between consecutive speckle images are efficiently estimated in the frequency domain, to produce vector maps up to 15 kHz PRF. Simulations and in vitro steady-flow experiments with different setup conditions have been conducted to thoroughly evaluate the method's performance. Bias is proved to be lower than 10% in most simulations and lower than 20% in experiments. Further simulations and in vivo experiments have been made to test the approach's feasibility in pulsatile flow conditions. It has been estimated that the computation of the frequency domain algorithm is more than 50 times faster than the computation of the reference 2-D cross-correlation algorithm.

Entities:  

Mesh:

Year:  2014        PMID: 25167150     DOI: 10.1109/TUFFC.2014.3064

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Coded Spectral Doppler Imaging: From Simulation to Real-Time Processing.

Authors:  Alessandro Ramalli; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-26       Impact factor: 2.725

2.  3-D Intravascular Characterization of Blood Flow Velocity Fields with a Forward-Viewing 2-D Array.

Authors:  Brooks D Lindsey; Bowen Jing; Saeyoung Kim; Graham C Collins; Muralidhar Padala
Journal:  Ultrasound Med Biol       Date:  2020-06-30       Impact factor: 2.998

3.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods.

Authors:  Enrico Boni; Luca Bassi; Alessandro Dallai; Francesco Guidi; Valentino Meacci; Alessandro Ramalli; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-11       Impact factor: 2.725

4.  3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.

Authors:  Jean Provost; Clement Papadacci; Charlie Demene; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

5.  Quest for the Vulnerable Atheroma: Carotid Stenosis and Diametric Strain--A Feasibility Study.

Authors:  Canxing Xu; Chun Yuan; Edward Stutzman; Gador Canton; Keith A Comess; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2015-12-23       Impact factor: 2.998

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.