Literature DB >> 25162252

A universal transvaginal cervical length screening program for preterm birth prevention.

Kelly M Orzechowski1, Rupsa C Boelig, Jason K Baxter, Vincenzo Berghella.   

Abstract

OBJECTIVE: To evaluate a universal transvaginal ultrasonogram cervical length screening program on the incidence of a cervical length 20 mm or less and adherence to the management protocol for a cervical length less than 25 mm.
METHODS: We conducted a prospective cohort study of women with singleton gestations 18 0/7 to 23 6/7 weeks of gestation eligible for universal transvaginal ultrasonogram cervical length screening over an 18-month period. Only women receiving antenatal care at our institution were included. Women with a prior spontaneous preterm birth and without delivery data available were excluded. A transvaginal ultrasonogram cervical length of less than 25 mm was managed according to a predetermined protocol. Primary outcomes were the incidence of a cervical length 20 mm or less and adherence to the management protocol for a cervical length less than 25 mm. Secondary outcomes were the incidences of spontaneous preterm birth at less than 37, less than 34, or less than 32 weeks of gestation among women undergoing transvaginal ultrasonogram cervical length screening compared with those not screened.
RESULTS: One thousand five hundred sixty-nine of 2,171 (72.3%) eligible women underwent transvaginal ultrasonogram cervical length screening. Overall, 17 (1.1%, 95% confidence interval [CI] 0.66-1.74) women had a cervical length 20 mm or less before 24 weeks of gestation. Management protocol deviations occurred in nine women with a cervical length less than 25 mm (43%, 95% CI 24.3-63.5). There was no difference in the incidence of spontaneous preterm birth at less than 37 weeks of gestation (4.1 compared with 4.7%, adjusted odds ratio [OR] 0.91, 95% CI 0.57-1.45), less than 34 weeks of gestation (1.5 compared with 1.3%, adjusted OR 1.19, 95% CI 0.52-2.74), or less than 32 weeks of gestation (0.8 compared with 0.8%, adjusted OR 0.0.76, 95% CI 0.26-2.25) among women receiving transvaginal ultrasonogram cervical length screening compared with those not screened.
CONCLUSION: In a universal transvaginal ultrasonogram cervical length screening program, the incidence of a cervical length 20 mm or less was 1.1% in women with singleton gestations without prior spontaneous preterm birth. Protocol deviations occurred in 43% of women with a cervical length less than 25 mm. The incidence of spontaneous preterm birth was similar among women undergoing transvaginal cervical length screening compared with those not screened. LEVEL OF EVIEDENCE: II.

Entities:  

Mesh:

Year:  2014        PMID: 25162252     DOI: 10.1097/AOG.0000000000000428

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  12 in total

1.  Universal cervical length screening: implementation and outcomes.

Authors:  Lorene A Temming; Jennifer K Durst; Methodius G Tuuli; Molly J Stout; Jeffrey M Dicke; George A Macones; Alison G Cahill
Journal:  Am J Obstet Gynecol       Date:  2016-02-10       Impact factor: 8.661

2.  Predictive Accuracy of Serial Transvaginal Cervical Lengths and Quantitative Vaginal Fetal Fibronectin Levels for Spontaneous Preterm Birth Among Nulliparous Women.

Authors:  M Sean Esplin; Michal A Elovitz; Jay D Iams; Corette B Parker; Ronald J Wapner; William A Grobman; Hyagriv N Simhan; Deborah A Wing; David M Haas; Robert M Silver; Matthew K Hoffman; Alan M Peaceman; Steve N Caritis; Samuel Parry; Pathik Wadhwa; Tatiana Foroud; Brian M Mercer; Shannon M Hunter; George R Saade; Uma M Reddy
Journal:  JAMA       Date:  2017-03-14       Impact factor: 56.272

Review 3.  Predicting preterm birth: Cervical length and fetal fibronectin.

Authors:  Moeun Son; Emily S Miller
Journal:  Semin Perinatol       Date:  2017-09-19       Impact factor: 3.300

4.  Shear wave elastography of the maternal cervix: A transabdominal technique.

Authors:  Sandra O'Hara; Marilyn Zelesco; Zhonghua Sun
Journal:  Australas J Ultrasound Med       Date:  2018-11-02

5.  Predicting asymptomatic cervical dilation in pregnant patients with short mid-trimester cervical length: A secondary analysis of a randomized controlled trial.

Authors:  Rupsa C Boelig; Lorraine Dugoff; Amanda Roman; Vincenzo Berghella; Jack Ludmir
Journal:  Acta Obstet Gynecol Scand       Date:  2019-02-27       Impact factor: 3.636

6.  Utility of follow-up cervical length screening in low-risk women with a cervical length of 26 to 29 mm.

Authors:  Rupsa C Boelig; Varsha Kripalu; Sarah L Chen; Yuri Cruz; Amanda Roman; Vincenzo Berghella
Journal:  Am J Obstet Gynecol       Date:  2021-02-27       Impact factor: 10.693

7.  Clinical and Cost Impact Analysis of a Novel Prognostic Test for Early Detection of Preterm Birth.

Authors:  Aaron B Caughey; John A F Zupancic; James M Greenberg; Susan S Garfield; Stephen F Thung; Jay D Iams
Journal:  AJP Rep       Date:  2016-10

Review 8.  Elastographic measurement of the cervix during pregnancy: Current status and future challenges.

Authors:  Hyunjung Kim; Han Sung Hwang
Journal:  Obstet Gynecol Sci       Date:  2017-01-19

9.  The Effect of a Universal Cervical Length Screening Program on Antepartum Management and Birth Outcomes.

Authors:  Scott A Shainker; Anna M Modest; Michele R Hacker; Steven J Ralston
Journal:  AJP Rep       Date:  2016-04

Review 10.  Vaginal progesterone for preventing preterm birth and adverse perinatal outcomes in singleton gestations with a short cervix: a meta-analysis of individual patient data.

Authors:  Roberto Romero; Agustin Conde-Agudelo; Eduardo Da Fonseca; John M O'Brien; Elcin Cetingoz; George W Creasy; Sonia S Hassan; Kypros H Nicolaides
Journal:  Am J Obstet Gynecol       Date:  2017-11-17       Impact factor: 8.661

View more