Literature DB >> 25161019

A pilot trial of bordered polyurethane dressings, tissue adhesive and sutureless devices compared with standard polyurethane dressings for securing short-term arterial catheters.

Melannie Edwards1, Claire M Rickard2, Ivan Rapchuk3, Amanda Corley2, Nicole Marsh4, Amy J Spooner2, Gabor Mihala4, John F Fraser2.   

Abstract

OBJECTIVES: To improve arterial catheter (AC) securement and reduce AC failure; to assess feasibility of a large randomised controlled trial. DESIGN, SETTING AND PARTICIPANTS: A four-arm, parallel, randomised, controlled, non-blinded pilot trial with 195 intensive care patients taking part, in a tertiary referral hospital in Brisbane, Australia from May to November 2012.
INTERVENTIONS: Standard polyurethane (SPU) dressing (controls); bordered polyurethane (BPU) + SPU dressing; tissue adhesive (TA) + SPU dressing; and sutureless securement device (SSD) + SPU dressing (no sutures used). MAIN OUTCOME MEASURES: AC failure, ie, complete dislodgement, occlusion (monitor failure, inability to infuse or fluid leaking), pain or infection (local or blood).
RESULTS: Median AC dwell time was 26.2 hours and was comparable between groups. AC failure occurred in 26/195 patients (13%). AC failure was significantly worse with SPU dressings (10/47 [21%]) than with BPU + SPU dressings (2/ 43 [5%]; P = 0.03), but not significantly different to TA + SPU (6/56 [11%]; P = 0.18) or SSD + SPU (8/49 [16%]; P = 0.61). The dressing applied at AC insertion lasted until AC removal in 68% of controls; 56% of BPU + SPU dressings; 73% of TA + SPU dressings; and 80% of SSD + SPU dressings (all P > 0.05). There were no infections or serious adverse events. Patient and staff satisfaction with all products was high. Median costs (labour and materials) for securement per patient were significantly higher in all groups compared with the control group (SPU, $3.48 [IQR, $3.48-$9.79]; BPU + SPU, $5.07 [IQR, $5.07-$12.99]; SSD + SPU, $10.90 [IQR, $10.90-$10.90]; TA + SPU, $17.70 [IQR, $17.70-$38.36]; all P < 0.01).
CONCLUSION: AC failure occurred significantly less often with BPU + SPU dressings than with SPU dressings. TA + SPU and SSD + SPU dressings should be further investigated and compared with BPU + SPU dressings as controls. The novel approach of TA + SPU dressings appeared safe and feasible.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25161019

Source DB:  PubMed          Journal:  Crit Care Resusc        ISSN: 1441-2772            Impact factor:   2.159


  5 in total

1.  Peripherally InSerted CEntral catheter dressing and securement in patients with cancer: the PISCES trial. Protocol for a 2x2 factorial, superiority randomised controlled trial.

Authors:  Claire M Rickard; Nicole M Marsh; Joan Webster; Nicole C Gavin; Raymond J Chan; Alexandra L McCarthy; Peter Mollee; Amanda J Ullman; Tricia Kleidon; Vineet Chopra; Li Zhang; Matthew R McGrail; Emily Larsen; Md Abu Choudhury; Samantha Keogh; Evan Alexandrou; David J McMillan; Merehau Cindy Mervin; David L Paterson; Marie Cooke; Gillian Ray-Barruel; Maria Isabel Castillo; Andrew Hallahan; Amanda Corley; E Geoffrey Playford
Journal:  BMJ Open       Date:  2017-06-15       Impact factor: 2.692

2.  Extracorporeal membrane oxygenation line-associated complications: in vitro testing of cyanoacrylate tissue adhesive and securement devices to prevent infection and dislodgement.

Authors:  Taressa Bull; Amanda Corley; Danielle J Smyth; David J McMillan; Kimble R Dunster; John F Fraser
Journal:  Intensive Care Med Exp       Date:  2018-03-12

3.  Comparative efficacy of 13 antimicrobial dressings and different securement devices in reducing catheter-related bloodstream infections: A Bayesian network meta-analysis.

Authors:  Fang-Ping Dang; Hui-Ju Li; Jin-Hui Tian
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

4.  What is the best catheter lock solution in preventing catheter-related blood infections? A protocol for a Bayesian network meta-analysis of randomised controlled trials.

Authors:  Fangping Dang; Huiju Li; Jinhui Tian; Ruijuan Wang; Jingjie Ren
Journal:  BMJ Open       Date:  2019-06-28       Impact factor: 2.692

5.  In vitro testing of cyanoacrylate tissue adhesives and sutures for extracorporeal membrane oxygenation cannula securement.

Authors:  India Pearse; Amanda Corley; Nicole Bartnikowski; John F Fraser
Journal:  Intensive Care Med Exp       Date:  2021-01-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.