Literature DB >> 25159422

An aptamer-based immunoassay in microchannels of a portable analyzer for detection of microcystin-leucine-arginine.

An Xiang1, Xiaoying Lei1, Fengling Ren2, Liuqin Zang3, Qin Wang1, Ju Zhang1, Zifan Lu4, Yanhai Guo5.   

Abstract

The rapid detection of microcystin-leucine-arginine (MC-LR), the most highly toxic among MCs, is significantly important to environmental and human health protection and prevention of MC-LR from being used as a bioweapon. Although aptamers offer higher affinity, specificity, and stability with MC-LR than antibodies in the immunodetection of MC-LR due to steric hindrance between two antibodies and limited epitopes of MC-LR for use in a sandwich immunoassay, no sandwich immunoassay using an aptmer has been developed for MC-LR detection. This study is aimed at developing an aptamer-antibody immunoassay (AAIA) to detect MC-LR using a portable analyzer. The aptamers were immobilized onto the glass surface of a microchamber to capture MC-LR. MC-LR and horseradish peroxidase (HRP)-labeled antibody were pulled into the microchamber to react with the immobilized aptamer. The chemiluminescence (CL) catalyzed by HRP was tested by a photodiode-based portable analyzer. MC-LR at 0.5-4.0 μg/L was detected quantitatively by the AAIA, with a CL signal sensitivity of 0.3 μg/L. The assay took less than 35 min for a single sample and demonstrated a high specificity, detecting only MC-LR, but not MC-LA, MC-YR, or nodularin-R. The recovery of two spiked real environmental samples calculated as 94.5-112.7%. Therefore, this AAIA was proved to be a rapid and simple method to detect MC-LR in the field by a single analyst.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Microcystin-leucine-arginine; Portable detection; Sandwich immunoassay

Mesh:

Substances:

Year:  2014        PMID: 25159422     DOI: 10.1016/j.talanta.2014.07.008

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Detection of microcystin-producing cyanobacteria in water samples using loop-mediated isothermal amplification targeting mcyB gene.

Authors:  Mohandass Ramya; Muthukrishnan Kayalvizhi; Gopalakrishnan Haripriya; Pasupathi Rathinasabapathi
Journal:  3 Biotech       Date:  2018-08-17       Impact factor: 2.406

Review 2.  Selection and Biosensor Application of Aptamers for Small Molecules.

Authors:  Franziska Pfeiffer; Günter Mayer
Journal:  Front Chem       Date:  2016-06-15       Impact factor: 5.221

Review 3.  Practical Application of Aptamer-Based Biosensors in Detection of Low Molecular Weight Pollutants in Water Sources.

Authors:  Wei Zhang; Qing Xiu Liu; Zhi Hou Guo; Jun Sheng Lin
Journal:  Molecules       Date:  2018-02-07       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.