Literature DB >> 25158021

A sensitive, simple and robust LC-MS/MS method for the simultaneous quantification of seven androgen- and estrogen-related steroids in postmenopausal serum.

Yuyong Ke1, Jonathan Bertin1, Renaud Gonthier1, Jean-Nicolas Simard1, Fernand Labrie2.   

Abstract

Steroids were first analyzed by immunoassay-based methods followed by gas chromatography mass spectrometry (GC-MS or GC-MS/MS) with derivatization techniques since steroids are neutral and do not ionize at a high level using the electrospray ionization technique. We now report a validated liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of seven steroidal compounds, i.e., estradiol (E2), estrone (E1), testosterone (Testo), dihydrotestosterone (DHT), androst-5-ene-3β, 17β-diol (5-diol), dehydroepiandrosterone (DHEA) and androstenedione (4-dione). The system used is a UPLC-MS/MS (Qtrap 6500) system. With this method, the sample preparation is the combination of liquid-liquid extraction and a simple selective derivatization for only E1 and E2. This assay method is simple and practically eliminates potential contamination. Low quantification limits of 1pg/mL, 4pg/mL, 50pg/mL, 10pg/mL, 100pg/mL, 500pg/mL and 100pg/mL have been found, respectively for the steroids mentioned above. Without derivatization, DHT sensitivity can be as low as 4pg/mL with S/N≥5. A full validation has been performed for the seven compounds in compliance with GLP and FDA guidelines for bioanalytical method development and validation. Recovery of all seven compounds in unstripped serum is similar to that in stripped serum: 72.1-84.7% for E2, 83.6-94.5% for E1, 88.2-90.3% for Testo, 82.0-90.6% for DHT, 84.9-92.0% for 5-diol, 88.1-93.8% for DHEA and 86.2-90.3% for 4-dione, respectively. A good linearity is obtained with R>0.99 for each compound within its calibration range. Accuracies of all levels of QC are within the range of 15% for all seven compounds. The between day variation coefficients are 6.1-8.9% for the low limits of quantification of all seven compounds with 0.7-6.1% for higher levels of QCs for all seven compounds. All results of other test parameters similarly meet the acceptance criteria of EndoCeutics SOPs and FDA guidelines. By comparison of GC-MS/MS and LC-MS/MS data for six derivatized and nonderivatized free steroids, the present data show the crucial importance to use validated assays according to the FDA guidelines to increase specificity, precision and reliability of the absolute values associated with MS/MS-based assays. This method has already been applied to series of samples from clinical trials and is ready for wide clinical use.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  17β-Diol; Androst-5- ene-3β; Androstenedione; Dehydroepiandrosterone; Dihydrotestosterone; Estradiol; Estrone; LC–MS/MS; Postmenopause; Sex steroids; Testosterone

Mesh:

Substances:

Year:  2014        PMID: 25158021     DOI: 10.1016/j.jsbmb.2014.08.015

Source DB:  PubMed          Journal:  J Steroid Biochem Mol Biol        ISSN: 0960-0760            Impact factor:   4.292


  21 in total

1.  Simultaneous quantitation of multiple contraceptive hormones in human serum by LC-MS/MS.

Authors:  Steven W Blue; Andrea J Winchell; Amy V Kaucher; Rachel A Lieberman; Christopher T Gilles; Maria N Pyra; Renee Heffron; Xuanlin Hou; Robert W Coombs; Kavita Nanda; Nicole L Davis; Athena P Kourtis; Joshua T Herbeck; Jared M Baeten; Jairam R Lingappa; David W Erikson
Journal:  Contraception       Date:  2018-01-31       Impact factor: 3.375

2.  Simultaneous quantitation of nine hydroxy-androgens and their conjugates in human serum by stable isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry.

Authors:  Tianzhu Zang; Daniel Tamae; Clementina Mesaros; Qingqing Wang; Meng Huang; Ian A Blair; Trevor M Penning
Journal:  J Steroid Biochem Mol Biol       Date:  2016-08-12       Impact factor: 4.292

3.  Steroid Sex Hormones, Sex Hormone-Binding Globulin, and Diabetes Incidence in the Diabetes Prevention Program.

Authors:  K J Mather; C Kim; C A Christophi; V R Aroda; W C Knowler; S E Edelstein; J C Florez; F Labrie; S E Kahn; R B Goldberg; E Barrett-Connor
Journal:  J Clin Endocrinol Metab       Date:  2015-07-22       Impact factor: 5.958

4.  A tandem liquid chromatography and tandem mass spectrometry (LC/LC-MS/MS) technique to separate and quantify steroid isomers 11β-methyl-19-nortestosterone and testosterone.

Authors:  Liang Tang; Robert R Swezey; Carol E Green; Min S Lee; Deborah I Bunin; Toufan Parman
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2022-02-09       Impact factor: 3.318

5.  β-Estradiol and ethinyl-estradiol contamination in the rivers of the Carpathian Basin.

Authors:  Péter Avar; Zita Zrínyi; Gábor Maász; Anikó Takátsy; Sándor Lovas; László G-Tóth; Zsolt Pirger
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-02       Impact factor: 4.223

6.  A sensitive and robust UPLC-MS/MS method for quantitation of estrogens and progestogens in human serum.

Authors:  Junmei Zhang; Chenxiao Tang; Patrick J Oberly; Margaret B Minnigh; Sharon L Achilles; Samuel M Poloyac
Journal:  Contraception       Date:  2019-01-24       Impact factor: 3.375

Review 7.  Ultra-high sensitivity analysis of estrogens for special populations in serum and plasma by liquid chromatography-mass spectrometry: Assay considerations and suggested practices.

Authors:  Qingqing Wang; Clementina Mesaros; Ian A Blair
Journal:  J Steroid Biochem Mol Biol       Date:  2016-01-06       Impact factor: 4.292

8.  Serum complexed and free prostate specific antigen levels are lower in female elite athletes in comparison to control women.

Authors:  Emma Eklund; Eleftherios P Diamandis; Carla Muytjens; Sarah Wheeler; Anu Mathew; Martin Stengelin; Eli Glezer; Galina Nikolenko; Marshall D Brown; Yingye Zheng; Angelica Lindén Hirschberg
Journal:  F1000Res       Date:  2017-07-17

9.  The effect of androgen excess on maternal metabolism, placental function and fetal growth in obese dams.

Authors:  Romina Fornes; Manuel Maliqueo; Min Hu; Laila Hadi; Juan M Jimenez-Andrade; Kerstin Ebefors; Jenny Nyström; Fernand Labrie; Thomas Jansson; Anna Benrick; Elisabet Stener-Victorin
Journal:  Sci Rep       Date:  2017-08-14       Impact factor: 4.379

10.  Label-Free Biosensor Detection of Endocrine Disrupting Compounds Using Engineered Estrogen Receptors.

Authors:  Rita La Spina; Valentina E V Ferrero; Venera Aiello; Mattia Pedotti; Luca Varani; Teresa Lettieri; Luigi Calzolai; Willem Haasnoot; Pascal Colpo
Journal:  Biosensors (Basel)       Date:  2017-12-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.