Literature DB >> 25155214

Multivariate analysis of factors predicting prostate dose in intensity-modulated radiotherapy.

Tsuneyuki Tomita1, Mitsuhiro Nakamura2, Yoshinori Hirose1, Kenji Kitsuda1, Takuya Notogawa1, Katsuhito Miki1, Kiyonao Nakamura3, Takashi Ishigaki3.   

Abstract

We conducted a multivariate analysis to determine relationships between prostate radiation dose and the state of surrounding organs, including organ volumes and the internal angle of the levator ani muscle (LAM), based on cone-beam computed tomography (CBCT) images after bone matching. We analyzed 270 CBCT data sets from 30 consecutive patients receiving intensity-modulated radiation therapy for prostate cancer. With patients in the supine position on a couch with the HipFix system, data for center of mass (COM) displacement of the prostate and the state of individual organs were acquired and compared between planning CT and CBCT scans. Dose distributions were then recalculated based on CBCT images. The relative effects of factors on the variance in COM, dose covering 95% of the prostate volume (D95%), and percentage of prostate volume covered by the 100% isodose line (V100%) were evaluated by a backward stepwise multiple regression analysis. COM displacement in the anterior-posterior direction (COMAP) correlated significantly with the rectum volume (δVr) and the internal LAM angle (δθ; R = 0.63). Weak correlations were seen for COM in the left-right (R = 0.18) and superior-inferior directions (R = 0.31). Strong correlations between COMAP and prostate D95% and V100% were observed (R ≥ 0.69). Additionally, the change ratios in δVr and δθ remained as predictors of prostate D95% and V100%. This study shows statistically that maintaining the same rectum volume and LAM state for both the planning CT simulation and treatment is important to ensure the correct prostate dose in the supine position with bone matching.
Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Interfraction displacement; Multivariate analysis; Prostate cancer

Mesh:

Year:  2014        PMID: 25155214     DOI: 10.1016/j.meddos.2014.06.004

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Dosimetric impact of organ at risk daily variation during prostate stereotactic ablative radiotherapy.

Authors:  Lynsey Devlin; David Dodds; Azmat Sadozye; Philip McLoone; Nicholas MacLeod; Carolynn Lamb; Suzanne Currie; Stefanie Thomson; Aileen Duffton
Journal:  Br J Radiol       Date:  2020-01-30       Impact factor: 3.039

2.  Performance evaluation of a newly developed three-dimensional model-based global-to-local registration in prostate cancer.

Authors:  Mitsuhiro Nakamura; Megumi Nakao; Hideaki Hirashima; Hiraku Iramina; Takashi Mizowaki
Journal:  J Radiat Res       Date:  2019-10-23       Impact factor: 2.724

  2 in total