Literature DB >> 25153732

Instrumental requirements for the detection of electron beam-induced object excitations at the single atom level in high-resolution transmission electron microscopy.

C Kisielowski1, P Specht2, S M Gygax3, B Barton4, H A Calderon5, J H Kang6, R Cieslinski6.   

Abstract

This contribution touches on essential requirements for instrument stability and resolution that allows operating advanced electron microscopes at the edge to technological capabilities. They enable the detection of single atoms and their dynamic behavior on a length scale of picometers in real time. It is understood that the observed atom dynamic is intimately linked to the relaxation and thermalization of electron beam-induced sample excitation. Resulting contrast fluctuations are beam current dependent and largely contribute to a contrast mismatch between experiments and theory if not considered. If explored, they open the possibility to study functional behavior of nanocrystals and single molecules at the atomic level in real time.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Keywords:  Aberration-correction; Catalysis; Functionality; Low dose imaging; Single atom sensitivity; TEM

Year:  2014        PMID: 25153732     DOI: 10.1016/j.micron.2014.07.010

Source DB:  PubMed          Journal:  Micron        ISSN: 0968-4328            Impact factor:   2.251


  4 in total

1.  A multifunctional biphasic water splitting catalyst tailored for integration with high-performance semiconductor photoanodes.

Authors:  Jinhui Yang; Jason K Cooper; Francesca M Toma; Karl A Walczak; Marco Favaro; Jeffrey W Beeman; Lucas H Hess; Cheng Wang; Chenhui Zhu; Sheraz Gul; Junko Yano; Christian Kisielowski; Adam Schwartzberg; Ian D Sharp
Journal:  Nat Mater       Date:  2016-11-07       Impact factor: 43.841

2.  Detecting structural variances of Co3O4 catalysts by controlling beam-induced sample alterations in the vacuum of a transmission electron microscope.

Authors:  C Kisielowski; H Frei; P Specht; I D Sharp; J A Haber; S Helveg
Journal:  Adv Struct Chem Imaging       Date:  2016-11-02

3.  In-line three-dimensional holography of nanocrystalline objects at atomic resolution.

Authors:  F-R Chen; D Van Dyck; C Kisielowski
Journal:  Nat Commun       Date:  2016-02-18       Impact factor: 14.919

4.  HRTEM low dose: the unfold of the morphed graphene, from amorphous carbon to morphed graphenes.

Authors:  H A Calderon; A Okonkwo; I Estrada-Guel; V G Hadjiev; F Alvarez-Ramírez; F C Robles Hernández
Journal:  Adv Struct Chem Imaging       Date:  2016-08-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.