Literature DB >> 25153004

Microarchitectural pattern of pristine maxillary bone.

Alberto Monje, Raúl González-García, Florencio Monje, Hsun-Liang Chan, Pablo Galindo-Moreno, Fernando Suarez, Hom-Lay Wang.   

Abstract

PURPOSE: There is limited evidence available on the influence of location on bone density in the maxilla. Therefore, this study was aimed at comparing the microarchitecture of bone harvested from different nonatrophic maxillary locations.
MATERIALS AND METHODS: A total of 37 partially edentulous subjects (aged 48.15 ± 15.85 years) were included in the study. A bone core biopsy specimen was obtained from one site per patient at the planned implant surgery location. Thirty-four specimens were used for microcomputed tomography (micro-CT) analysis. Mann-Whitney U tests (independent samples) were performed to determine whether the distributions of the six bone-related parameters showed significant differences between sexes and site locations. Study sites were categorized as either anterior (incisors and canines) or posterior (premolars and molars). The possible associations among variables (bone volume fraction [BV/TV], age, and five bone-related parameters) were examined using the Spearman rank correlation test.
RESULTS: The mean BV/TV values showed no significant difference between the maxillary anterior (46.93 ± 26.2) and posterior (51.90 ± 28.42) locations. Statistically significant positive correlations were identified between BV/TV and trabecular thickness (Tb.Th) (r = 0.6, P < .001) and between BV/TV and trabecular number (Tb.N) (r = 0.49, P = .006). Statistically significant negative correlations were found between BV/TV and trabecular spacing (Tb.Sp) (r = -0.65, P < .001), between BV/TV and trabecular pattern factor (Tb.Pf) (r = -0.7, P <.001), and between BV/TV and the structural model index (SMI) (r = -0.68, P <.001). However, no correlations between BV/TV and age or sex were found.
CONCLUSION: Bone density was independent of the anatomical location, assessed by micro-CT in the pristine nonatrophic maxillary bone. Studies with a larger sample size and different population should be conducted to validate the findings of the current project.

Entities:  

Mesh:

Year:  2014        PMID: 25153004     DOI: 10.11607/jomi.3681

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Relationships among Bone Quality, Implant Osseointegration, and Wnt Signaling.

Authors:  J Li; X Yin; L Huang; S Mouraret; J B Brunski; L Cordova; B Salmon; J A Helms
Journal:  J Dent Res       Date:  2017-03-22       Impact factor: 6.116

2.  Effects of Condensation on Peri-implant Bone Density and Remodeling.

Authors:  L Wang; Y Wu; K C Perez; S Hyman; J B Brunski; U Tulu; C Bao; B Salmon; J A Helms
Journal:  J Dent Res       Date:  2017-01-03       Impact factor: 6.116

3.  Presurgical Cone Beam Computed Tomography Bone Quality Evaluation for Predictable Immediate Implant Placement and Restoration in Esthetic Zone.

Authors:  Corina Marilena Cristache
Journal:  Case Rep Dent       Date:  2017-02-22

Review 4.  Maxillary Sinus Floor Augmentation with Autogenous Bone Graft Alone Compared with Alternate Grafting Materials: a Systematic Review and Meta-Analysis Focusing on Histomorphometric Outcome.

Authors:  Thomas Starch-Jensen; Daniel Deluiz; Niels Henrik Bruun; Eduardo Muniz Barretto Tinoco
Journal:  J Oral Maxillofac Res       Date:  2020-11-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.