Literature DB >> 25153001

Zygomatic implants as a rehabilitation approach for a severely deficient maxilla.

Ahmad M Al-Thobity, Glenn J Wolfinger, Stephen F Balshi, Robert J Flinton, Thomas J Balshi.   

Abstract

A gunshot injury is one of the main trauma injuries that affect the head and neck region. Severe esthetic, functional, and psychologic deficiencies are consequences of gunshot injuries. The use of implants anchored in the zygomatic bone has been advocated as an approach to the prosthetic rehabilitation of a severely deficient maxilla. This approach provides the patient with an immediate, high-quality, esthetic, and functional complete fixed prosthesis and eliminates the need for bone grafting. In this case report, a patient with a severely deficient maxilla caused by a gunshot injury was rehabilitated by placement of four zygomatic and two pterygomaxillary implants, which were immediately loaded with a complete fixed all-acrylic resin interim prosthesis. The definitive CM Prosthesis (CM Prosthetics) was constructed using computer-aided design/computer-assisted manufacture (CAD/CAM) technology.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25153001     DOI: 10.11607/jomi.3662

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Custom-made 3D printed subperiosteal titanium implants for the prosthetic restoration of the atrophic posterior mandible of elderly patients: a case series.

Authors:  Carlo Mangano; Andrea Bianchi; Francesco Guido Mangano; Jessica Dana; Marco Colombo; Ivan Solop; Oleg Admakin
Journal:  3D Print Med       Date:  2020-01-08

Review 2.  Success Rates of Zygomatic Implants for the Rehabilitation of Severely Atrophic Maxilla: A Systematic Review.

Authors:  Aleix Solà Pérez; David Pastorino; Carlos Aparicio; Marta Pegueroles Neyra; Rabia Sannam Khan; Simon Wright; Cemal Ucer
Journal:  Dent J (Basel)       Date:  2022-08-12

3.  Surgical complications in zygomatic implants: A systematic review.

Authors:  P Molinero-Mourelle; L Baca-Gonzalez; B Gao; L-M Saez-Alcaide; A Helm; J Lopez-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-11-01

4.  Custom-Made Direct Metal Laser Sintering Titanium Subperiosteal Implants: A Retrospective Clinical Study on 70 Patients.

Authors:  Mauro Cerea; Giorgio Andrea Dolcini
Journal:  Biomed Res Int       Date:  2018-05-28       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.