Literature DB >> 25151468

Examining Hemodialysis Reliable Outflow catheter performance and cost in hemodialysis access.

Daniel J Torrent1, Mandy R Maness1, Swapnil D Kachare1, Jill N Zink2, Carl E Haisch1, Robert C Harland1, Claire Morgan1, Rodney L Guyton3, Avery G Colomb3, David W Barham3, Eric C Katz3, Michael C Stoner4.   

Abstract

BACKGROUND: The Hemodialysis Reliable Outflow (HeRO) vascular access device is a hybrid polytetrafluoroethylene graft-stent construct designed to address central venous occlusive disease. Although initial experience has demonstrated excellent mid-term patency rates, subsequent studies have led to external validity questions. The purpose of this study was to examine a single center experience with this vascular access device in challenging access cases with associated costs.
METHODS: A retrospective study representing the authors' cumulative HeRO vascular access device experience was undertaken. The primary endpoint was graft failure or death, with secondary endpoints including secondary intervention rates and cost.
RESULTS: Forty-one patients with 15,579 HeRO days and a mean of 12.7 ± 1.5 mo with the vascular access device were available for analysis. Secondary patency was 81.6% at 6 mo and 53.7% at 12 mo. The reintervention rate was 2.84 procedures per HeRO vascular access device year. Associated HeRO costs related to subsequent procedures were estimated at $34,713.63 per patient/y.
CONCLUSIONS: These data on the patency and primary outcome data diverge significantly from initial multicenter studies and represent a real-world application of this technology. It is costly to maintain patency. Use of HeRO vascular access devices should be judicious with outcome expectations reduced.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Arteriovenous graft; HeRO; Hemodialysis; Hemodialysis Realiable Outflow; Hemodialysis access; Vascular access

Mesh:

Year:  2014        PMID: 25151468     DOI: 10.1016/j.jss.2014.03.016

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  2 in total

1.  Multidisciplinary team approach to end-stage dialysis access patients.

Authors:  Clark Kensinger; Evan Brownie; Peter Bream; Derek Moore
Journal:  J Surg Res       Date:  2015-05-06       Impact factor: 2.192

Review 2.  Vascular Access for Placement of Tunneled Dialysis Catheters for Hemodialysis: A Systematic Approach and Clinical Practice Algorithm.

Authors:  Keith Pereira; Adam Osiason; Jason Salsamendi
Journal:  J Clin Imaging Sci       Date:  2015-05-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.