Literature DB >> 25148163

Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase.

William P Shuman1, Douglas E Green, Janet M Busey, Lee M Mitsumori, Eunice Choi, Kent M Koprowicz, Kalpana M Kanal.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the effect of use of dual-energy CT monochromatic imaging in the late hepatic arterial phase on hyperenhancing focal lesion detection and lesion conspicuity. SUBJECTS AND METHODS: This prospective study included 72 patients imaged with a single-source dual-energy CT scanner. Late arterial phase imaging was performed with dual energies of 140 and 80 kVp, and the portal venous and delayed phases were performed with a single energy of 120 kVp. Two deidentified image sets were created: set A consisted of 77-keV images only, and set B consisted of 40-, 50-, 70-, and 77-keV images and iodine-based contrast material decomposition images. Two independent reviewers identified hypervascular lesions and subjectively scored lesion conspicuity. Contrast-to-noise ratios were calculated, and radiation dose (volume CT dose index) was recorded.
RESULTS: The 128 lesions identified had a mean size of 1.7 ± 1.4 cm. There was no difference in lesion detection between the two reviewers or the two image sets. The contrast-to-noise ratio at 50 keV was 72% greater than that at 77 keV (p < 0.0001). Subjective conspicuity was statistically greatest at 50 keV (p < 0.0001). There was no statistical difference in mean volume CT dose index between the dual-energy (12.8 mGy) and the two single-energy (14.4 and 14.2 mGy) phases.
CONCLUSION: Viewing dual-energy CT images may result in the greatest subjective lesion conspicuity and measured contrast-to-noise ratio at 50 keV with equal detection of hyperenhancing liver lesions compared with viewing 77-keV images alone. In addition, the radiation doses of dual-energy CT may be similar to those of single-energy CT.

Entities:  

Keywords:  cirrhosis; dual-energy CT; fast kilovoltage switching; hepatocellular carcinoma; liver CT

Mesh:

Year:  2014        PMID: 25148163     DOI: 10.2214/AJR.13.11337

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  27 in total

Review 1.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

Review 2.  "How to" incorporate dual-energy imaging into a high volume abdominal imaging practice.

Authors:  Eric P Tamm; Ott Le; Xinming Liu; Rick R Layman; Dianna D Cody; Priya R Bhosale
Journal:  Abdom Radiol (NY)       Date:  2017-03

3.  Improving iodine contrast to noise ratio using virtual monoenergetic imaging and prior-knowledge-aware iterative denoising (mono-PKAID).

Authors:  Shengzhen Tao; Kishore Rajendran; Wei Zhou; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Phys Med Biol       Date:  2019-05-16       Impact factor: 3.609

4.  Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms.

Authors:  Nils Große Hokamp; V Neuhaus; N Abdullayev; K Laukamp; S Lennartz; A Mpotsaris; J Borggrefe
Journal:  Skeletal Radiol       Date:  2017-09-21       Impact factor: 2.199

5.  A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions.

Authors:  Carlo N De Cecco; Damiano Caruso; U Joseph Schoepf; Domenico De Santis; Giuseppe Muscogiuri; Moritz H Albrecht; Felix G Meinel; Julian L Wichmann; Philip F Burchett; Akos Varga-Szemes; Douglas H Sheafor; Andrew D Hardie
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

6.  Automatic spectral imaging protocol and iterative reconstruction for radiation dose reduction in typical hepatic hemangioma computed tomography with reduced iodine load: a preliminary study.

Authors:  Wei Li; Aiyin Li; Bin Wang; Xiuyuan Niu; Xin Cao; Xinyi Wang; Hao Shi
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

7.  Dual-energy CT arthrography: a feasibility study.

Authors:  Rashpal Sandhu; Mercan Aslan; Nancy Obuchowski; Andrew Primak; Wadih Karim; Naveen Subhas
Journal:  Skeletal Radiol       Date:  2020-09-18       Impact factor: 2.199

8.  Inter-scan and inter-scanner variation of quantitative dual-energy CT: evaluation with three different scanner types.

Authors:  Simon Lennartz; Anushri Parakh; Jinjin Cao; David Zopfs; Nils Große Hokamp; Avinash Kambadakone
Journal:  Eur Radiol       Date:  2021-01-14       Impact factor: 5.315

9.  Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams.

Authors:  Usman Mahmood; Natally Horvat; Joao Vicente Horvat; Davinia Ryan; Yiming Gao; Gabriella Carollo; Rommel DeOcampo; Richard K Do; Seth Katz; Scott Gerst; C Ross Schmidtlein; Lawrence Dauer; Yusuf Erdi; Lorenzo Mannelli
Journal:  Eur J Radiol       Date:  2018-02-19       Impact factor: 3.528

10.  Impact of Photon Counting Detector Technology on kV Selection and Diagnostic Workflow in CT.

Authors:  Wei Zhou; Dilbar Abdurakhimova; Michael Bruesewitz; Ahmed Halaweish; Cynthia H McCollough; Shuai Leng
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.